background image

3

FOOD-6006-01

PRODUCT OVERVIEW

The QuickSTAR

 Horizon

 Strip Reader is a hand-held instrument designed to quickly read 

and analyze lateral flow and dry chemistry test strips from PerkinElmer . The unit provides 
qualitative and fully quantitative test results in less than ten seconds .  

Key Features

•  Touchscreen interface

•  Ergonomically designed for easy use in the field or lab

•  USB compatibility

•  Automatic internal calibration at startup

•  Remotely upgradeable software updates

•  Internal 2D barcode reader

Additionally, the QuickSTAR

 Horizon

 Strip Reader features a rechargeable internal 

lithium-ion battery, and printer connectivity options . The QuickSTAR

 Horizon

 Strip 

Reader comes with the Data Manager Desktop Suite™, which allows the user to easily 
transfer data from the unit to a Windows 7/8/10 laptop or desktop computer and to view, 
archive, print, and export all test results .

Please take time to familiarize yourself with the unit’s features and setup prior to testing . 
For technical support, email 

Bioo .Support@PerkinElmer .com

 or call 1-888-208-2246 or 

1-512-707-8993 .

Summary of Contents for QuickSTAR Horizon

Page 1: ...TM OPERATIONS MANUAL Catalog FOOD 6006 01 MN50 6006 01 Rev A...

Page 2: ...t notice If you find information in this document that is incorrect misleading or incomplete PerkinElmer would appreciate your comments and suggestions QuickSTAR Horizon Strip Reader is intended as a...

Page 3: ...p Remotely upgradeable software updates Internal 2D barcode reader Additionally the QuickSTAR Horizon Strip Reader features a rechargeable internal lithium ion battery and printer connectivity options...

Page 4: ...l maintain its current power state A dialog box will display to notify the user when the battery needs to be charged For peak battery life and performance it is recommended to use the Total Power Down...

Page 5: ...d numbers Select to temporarily use uppercase letters for a single letter Select 123 to alternate between letters and symbols THEORY OF OPERATION Inserting an adapter containing a lateral flow test st...

Page 6: ...routine then return to the Main menu and allow the user to choose another Category and or Test Viewing Test Results After each test is run the results are displayed with captured images of the test st...

Page 7: ...cord plugged into the left side of the reader Click the icon to connect the reader and choose the USB connection option Launch PerkinElmer Data Manager Click on Import Browse Data in the left sidebar...

Page 8: ...s will display either Passed or Out of Date If the device is due for calibration the user will see Please Calibrate and should select Start to perform the unit calibration routine Unit Calibration Rou...

Page 9: ...and then delete the name no longer needed once it switches into Select Other category CHANGING TIME From the screen select User Preferences Click on the in the top right of the screen Select Time Cli...

Page 10: ...te the Main Menu will display Hard Reboot After Freeze If a Soft Reboot is not possible the QuickSTAR Horizon strip reader will need to be hard rebooted to resolve an issue To reboot the unit perform...

Page 11: ...Horizon strip reader is connected to a computer Once connected launch the Data Manager to import the results WiFi status The unit can be connected to the wireless network and the results uploaded to t...

Page 12: ...8993 www biooscientific com For a complete listing of our global offices visit www perkinelmer com ContactUs Copyright 2019 PerkinElmer Inc All rights reserved PerkinElmer is a registered trademark o...

Reviews: