3. Hot tank water heater.
During the periods of maintaining steady temperature hot tank operates in silent mode.
When water is dispensed or pre-heat button is activated Turbo function will emit “kettle”
like moderate sound few minutes before it reaches the required temperature.
4. Refrigeration compressor works when water needs to be cooled. It has very low pitch
humming noise like your refrigerator
5. In some cases sound resulting from installation on hard flooring is present. Place Sound
absorbing mat under your cooler to eliminate this noise. Mat is supplied with your cooler.
COMPARISON BETWEEN AND OTHER BRAND WATER
COOLER AND COFFEE BREWER
Model
Self Clean
Compressor power/current
Hot tank power/Current
Cold water peak hour output
below 50
0
F in gal/hour
Cold water peak hour output
below 46
0
F in gal/hour
Cold water peak hour output
below 43
0
F in gal/hour
Hot tank Volume and power
Hot water peak hour output
above 176
0
F
Lowest Hot Water Tank temperature
Highest Hot Water temperature,
measured in the brewer pot
Energy Efficiency, Use electricity
in 24 Hours
Pre-heat time for each draw
of coffee cup
Water temperature in brew pot
Brewer controls
Water Supply Volume
Stainless steel front panels
Other water cooler
not available
81.2W/1.05A
445 Watts
0.95 gal/hr
0.63 gal/hr
0 gal/hr
33.8 oz 445W
1.53 gal/hr
above 176
0
F
78
0
C/172
0
F
n/a
1.0268 KWH
No
8HCH-KK-SSF-2/1POU
Yes
96.5W/1.148A
1400 Watts
1.59 gal/hr
0.92 gal/hr
0.66 gal/hr
40.6 oz 1400 Watts
2.64 gal/hr above 194
0
F
90
0
C/194
0
F
94
0
C/201
0
F
830 Watts
instant, 6 continuous draws,
no waiting period (for futures)
94
0
C/201
0
F
intuitive, with sequential green
lights guiding the way. no need
for manual to operate
Yes
Other single serve coffee brewer
not applicable
not applicable
1500 Watts
not applicable
not applicable
not applicable
cup size volume 4,6,8,10
and 12 oz filled each time
and then heated. 1500 Watts
not applicable
room temperature
89
0
C/192
0
F
depending on usage
first cup 29 seconds
for 8 oz cup 17 seconds
for second cup
86
0
C~89
0
C
/187
0
F~192
0
F
confusing, cannot
operate easily without
reading manual
0.58 gallon/2.2 L
Continuous supply from city mains
5 gallon/18.9 L
No
Voltage / Frequency: 120V/60Hz
5