background image

                                                                 www.propa.care

 

 

 

 

 
The 

ozone  on-demand

 

feature  provides  an  additional  and  powerful  layer  of 

security  for  your  environment,  allowing  a  sanitization  effect  to  occur  with  the 
space. 
 
The  positive  bactericidal  effect  of  the  technology  increases  defenses  against 

germs

, becoming a valid means to neutralize odors, which are absorbed thanks to 

the action of activated oxygen ions. 

  

The 

JoyBion  400

 

can  be  used  as  an  air 

purifier  combined  with  a  2-step  prefiltration 
process  –  electrostatic  and  activated  carbon 
filters  -  enhanced  by  controlled  bipolar 
ionization. 

 

Thanks to the unique emission of ions, the electrostatic filter removes from the air 
solid  impurities  up  to  a  diameter  of  0.1  μm.  The  activated  carbon  filter  assists  to 
remove VOC’s, as well as unpleasant odors, from the environment. 

 

Simultaneously  the  addition  of  positive  ions 
and negative ions to the air in the room, allows 
to  neutralize  and  remove  unwanted  particles 
from  the  air,  revitalizing  the  air  in  a  natural 
way. 

 

The  bipolar  ionization  metering  system  is  the 
subject  of  an 

international  patent

 

by  Periso 

SA

,  and  allows  to  reproduce  the  natural 

ionization which happens in nature, where the 
air is fresh and clean. 

 

The 

SOLS Magma 13 Bionomic Module

 

is a Swiss technology, designed by SOLS, 

that generates nanomechanical vibration which in turn diffuse the energization and 
harmonization  process.  This  module  increases  the  natural  ambient  energy 
produced by the unit.  
 
The 

JoyBion 400

 

is designed by SOLS and produced by Periso exclusively for the 

Propacare Division of Propagroup.

 

 

Summary of Contents for SOLS Propacare JoyBion 400

Page 1: ...AIR PURIFICATION IONIZATION SANIFICATION USER MANUAL AND MAINTENANCE ...

Page 2: ...nologies for medical and industrial applications able to improve everyone s quality of life For over three decades Periso SA has specialized in the sectors of biomedicine energy industrial assembly and air treatment providing ground breaking and unique technological developments driven by a strong commitment to research and Swiss quality www periso ch ...

Page 3: ...DEX 1 Benefits of the Technology page 4 2 Reference Directives and Regulations page 6 3 Warnings page 8 4 Instructions for Use page 9 5 Maintenance page 11 6 Technical Data page 16 7 Warranty page 17 8 Annotations page 18 ...

Page 4: ...ological effects it entails and for the wide range of applications The technology of controlled bipolar ionization has a positive result for the health of people as it has a beneficial influence on human health stress and cognition Bipolar ionization is a well researched and utilized technology often found in schools hospitals airports restaurants and many commercial and industrial air systems The...

Page 5: ...ter of 0 1 μm The activated carbon filter assists to remove VOC s as well as unpleasant odors from the environment Simultaneously the addition of positive ions and negative ions to the air in the room allows to neutralize and remove unwanted particles from the air revitalizing the air in a natural way The bipolar ionization metering system is the subject of an international patent by Periso SA and...

Page 6: ...l aria EN 61000 6 3 Compatibilità elettromagnetica EMC Prescrizioni per gli elettrodomestici gli utensili elettrici e gli apparecchi similari Emissione EN 61000 6 1 Compatibilità elettromagnetica Requisiti di immunità per gli elettrodomestici gli utensili elettrici e gli apparecchi similari Immunità EN 61000 3 2 Compatibilità elettromagnetica EMC Limiti per le emissioni di corrente armonica EN 610...

Page 7: ...me alla Direttiva 2014 35 UE relativa alla bassa tensione LVD directive alla Direttiva 2014 30 UE relativa alla compatibilità elettromagnetica EMC directive Direttiva RAEE 2012 19 UE sui Rifiuti di Apparecchiature Elettriche ed Elettroniche Directive on Waste Electrical and Electronic Equipment WEEE Direttiva ROHS 2011 65 CE sul divieto di utilizzo di determinate sostanze nelle apparecchiature Ele...

Page 8: ...ating in high voltage Do not open or tamper with the ionizer while it is electrically powered and in operating mode Don t touch the electrodes see point 5 with device switched on Temperature Do not bring the ionizer devices near open flames or other high temperature sources Humidity Do not use the ionizing devices in excessively humid environments that may compromise correct operation of the devic...

Page 9: ...n 400 should be placed at least 2 m away from televisions computers humidifiers and heat sources The JoyBion 400 can be put into operation immediately Its use is very simple a Insert the plug into a power outlet with voltage 220 240VAC 50 60 Hz b Position the ignition switch on the back of the device on I The device is now in stand by mode On the front of the device there is a LCD screen Red butto...

Page 10: ... Speed Using the green button Ionize it is possible to turn off the ionization and the icon that appears on the screen is the following To activate ozone production use the red button Sanitize When ozone production is active the red LED lights up and the fan speed is automatically set to medium level The following icon appears on the screen The time also appears on the screen set using the red but...

Page 11: ...g on Press to Open Electrostatic filter white should be changed 2 4 times per year and activated carbon filter black should be changed twice a year Failure to replace the filters entails the deposit of dust and dirt inside the device with possible risk of damage to the fan with increased noise emitted The environmental conditions in which the device is placed may be such that as to suggest the use...

Page 12: ...move the upper cover by pressing on Press to Open Remove the grill containing the filters by lifting it sideways from the rear Remove the filters and replace the new ones by inserting them correctly and in the same order Grid containing filters ...

Page 13: ...red circles in the previous image in the fins on the internal grid indicated by the red circles in the right image then lower the grid onto the base to ensure the spring lock Close the device by placing the top cover b Carbon fiber electrodes It is recommended not to obstruct the front of the appliance for a correct bipolar ionization emission ...

Page 14: ...rder to avoid damages or electrode fibers bending In order to guarantee the efficiency of bipolar ionization it is necessary to remove the dust that can accumulate on the ionizing fibers 1 2 times per month Environments with higher levels of dust should clean the electrodes every 15 days c Glass Electrodes It is recommended once a year to clean the glass electrodes to remove the dust that has sett...

Page 15: ...xing screws with an M3 wrench moving it forward a few millimeters and finally lifting it Clean the glass electrodes indicated by the red circle in the previous image and the motor without force on the blades with the supplied antistatic brush ESD taking care not to damage any component Repeat the operations in reverse to reassemble the appliance ...

Page 16: ... 90 m2 Ionization strength 280 000 ions cm3 ventilation at min 390 000 ions cm3 ventilation at max For rooms up to 100 m2 Nominal Air flow 220m3 h at max Fan Tangential fan suitable for continuous operation ball bearings Filters 1 Electrostatic filter and 1 Activated carbon filter replaceable Dimensions 482 x 332 x 140 mm LxWxH Weight 8 kg Command Manual Installation Portable Measurements were mad...

Page 17: ...se limited warranty conditions that is found to be defective within the scope of normal and appropriate use and are within the two 2 Year Warranty period Warranty claims must include receipt of purchase to validate warranty and optimally the original box of the unit for shipping Please have this information available when contacting customer service For warranty service in the European Union visit...

Page 18: ...__________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ __________________________________...

Page 19: ...______________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______...

Page 20: ...www propa care 20 JoyBion 400_V01D_EN ...