USE AS SIMPLE WEIGHT INDICATOR

Switch the indicator on with the key           and wait for a few seconds. After the HELLO
message, the indicator shows the model and the version and prepares itself for direct reading.
Load  and  you  will  immediately  read  the  value  corresponding  to  the  loaded  weight.
NB: in the beginning it might be necessary to adjust the zero, because the mechanical parts
of the system need some time to settle.

ZEROING (TARE)

Switch the indicator on, after a few seconds a value will be displayed. Keep the             key
pressed until the display shows the message tArE. The indicator goes automatically to zero.

PARTIAL WEIGHINGS

To make loading of different ingredients easier, without using the alarm, press             and
the display will visualize "0" with an indicator which will set on NET. Load the ingredient,
press             again and the indicator will move to TOTAL so that the total loaded weight will
be shown. Follow this procedure for all the partial weighings (loading and unloading).

SELECTION OF FUNCTIONS

To change the function you only need to press             .
The fixed announcer will move showing each time the selected function:
TOTAL / NET / EXECUTION / PROGRAMMING / STORAGE.

PROGRAMMING RATIONS

FarmScale Mod. 700/710 has a memory able to store programmes of 20 recipes of 20
ingredients each, which can be used for loading and unloading.
When executing the ration, the indicator automatically recognizes if a loading or unloading
is being carried out (LOAD/UNLO announcers); there will be an alarm both for loading and
for unloading. It is therefore possible to use the programming of recipes to manage different
unloading groups, too.

There are two different ways of setting the programming:
- in total values (the ingredients are expressed in total kilos)
- proportional to the number of animals (the ingredients are expressed per animal)
To write, recall, check and execute the programme, use the keys placed on the frontal panel.
The user should prepare a list of all the ingredients with their values in order to program the
recipe in a correct way.

PROGRAMMING LOADING IN TOTAL VALUES

The ingredients are introduced in total Kg. After the ration has been entered, before executing
it, it is still possible to change the total value with automatic adaptation of components.
e.g. - program the recipe n. 1 composed of the following ingredients: n. 1 of 110 kg, n. 2 of
225 kg, n. 3 of 1120 kg and n. 4 of 120 kg. Proceed in this way: switch on the indicator and
wait for a few seconds.

Summary of Contents for Farm Scale 700

Page 1: ...Viale A Moro 7 26845 CODOGNO LO ITALY Tel 39 0377 43 70 33 Fax 43 70 46 www farmscale com e mail info farmscale com ...

Page 2: ...USERS HANDBOOK mod 700 710 English ...

Page 3: ...ramming loading in total values 6 Loading ration N 1 total values 8 Programming per number of animals 9 Loading ration N 2 number of animals 10 Programming unloading groups 11 Unloading ration N 3 groups 12 Extra Functions 13 HOLD function weight freeze 13 Programmed weight restore function 13 Selecting automatic manual passage 13 Storage function 13 Troubles and solutions 14 System representation...

Page 4: ...e device is used If during the warranty period one or more components are replaced for the reparation with spare parts which are not supplied or approved by the producer or in case reparation is carried out by non authorized people Perin Weighmaster S r l reserves the right to revoke immediately the warranty with no further information Warranty is appliable only if there are the producer s label a...

Page 5: ...emove the weight indicator from the machine and protect the connectors of the cables from water seepage Pay attention that the load cells the junction box the alarm and other accessories are not exposed to direct waterjets If the device needs to be cleaned use soft and lightly humid cloths Do not use sprays solvents abrasives sharp or cutting objects which could damage the case Do not open the dev...

Page 6: ... scale tare Zeroes the wrong values kept pressed it goes back to direct reading Restores the value of a programmed ingredient kept pressed it goes back to direct reading Selects the functions of recipes recall programming and storage Memorizes the digit and passes to the next one Passes to the following ingredient manual or automatic DESCRIPTION OF THE DEVICE indicators of recipe and ingredient n ...

Page 7: ...ed no cuts nor abrasions Remember that where food is stored or handled small rodents often gnaw cables which are situated in hidden or scarcely reachable places 6 Check there is no oxidation or humidity on the connecting points 7 Check that the silicone used to seal the different parts of the weighing system is intact otherwise there could be water seepage BATTERY TEST The battery test should be m...

Page 8: ...ion TOTAL NET EXECUTION PROGRAMMING STORAGE PROGRAMMING RATIONS FarmScale Mod 700 710 has a memory able to store programmes of 20 recipes of 20 ingredients each which can be used for loading and unloading When executing the ration the indicator automatically recognizes if a loading or unloading is being carried out LOAD UNLO announcers there will be an alarm both for loading and for unloading It i...

Page 9: ...emorizes the second digit it increases the third digit hundreds it memorizes the value of ingredient n 1 and displays the value of ingredient n 2 it increases the value of the first digit units it memorizes the first digit it increases the value of the second digit tens it memorizes the second digit it increases the value of the third digit hundreds it memorizes the value of ingredient n 2 and dis...

Page 10: ... displays the loading function the indicator moves to EXECUTION it confirms the loading function and displays the total of the ration n 1 The right digit blinks to indicate that it is possible to change the total of the ration with adaptation of the ingredients it confirms the execution of the ration n 1 and displays the ingredient n 1 ready for loading The announcers blink on EXECUTION and LOAD a...

Page 11: ...he total of the recipe n 1 will be displayed it increases the number of the recipe it confirms the recipe n 2 it asks for the number of animals the right digit blinks it increases the first digit units it memorizes the first digit and displays the second one it increases the second digit tens it memorizes the second digit it increases the third digit hundreds it memorizes the number of animals and...

Page 12: ...of the ingredient n 3 it memorizes the first digit dag it increases the second digit hg it memorizes the second digit it increases the third digit kg it memorizes the value of the ingredient n 3 and displays the value of the ingredient n 4 it increases the first digit dag it memorizes the first digit it increases the second digit hg press several times to scroll the other values up to the 20th ing...

Page 13: ...ls the value of the first ingredient ready to be loaded is displayed The announcers blink on EXECUTION and LOAD at the same time Load the value on the display will decrease in proportion to the loaded amount When 85 of the load has been reached you will hear an intermittent signal load with care When 100 has been reached you will hear a continuous signal stop loading immediately After 5 seconds th...

Page 14: ...ress it once more to store the second digit tens it increases the value of the third digit hundreds it memorizes the third digit it increases the value of the fourth digit thousands Press several times to scroll the other values up to number 20 The total of the recipe will be displayed To leave the PROGRAM function press it displays the unloading function indicator over EXECUTION Press it twice to...

Page 15: ...unloading of a recipe the passage to the following ingredient is automatic after 5 seconds of alarm To have manual passage press LOAD UNLO fixed indicator When the programmed quantity is reached the alarm goes on sounding and you have to press to proceed with the following ingredient SELECTING AUTOMATIC MANUAL PASSAGE When 85 of the unloading has been reached you will hear an intermittent signal t...

Page 16: ...oing while the container is empty Make sure that there are no disturbing elements between chassis and counterchassis Put a test weight on every corner possibly near the load cell to locate the damage Ask for technical assistance check the binary connector Use a 12 volt battery to supply the alarm device separately Substitute it with a new alarm if necessary out of range high or low check the conne...

Page 17: ...RAMMING STORAGE LOADING UNLOADING PROGRAMMABLE DIVISIONS 1 2 5 10 20 MAXIMUM RESOLUTION 24 BITS MEMORY FOR 20 RECIPES EACH ONE WITH 20 INGREDIENTS PROGRAMMING WITH NUMBER OF ANIMALS OR IN TOTAL VALUES AUTOMATIC PROPORTIONAL CALCULATION OF EACH INGREDIENT ACCORDING TO THE PLANNED NUMBER OF ANIMALS INGREDIENTS CAN BE USED BOTH FOR LOADING AND FOR UNLOADING NOTICE AT 85 ALARM FOR 5 sec WHEN LOADING U...

Page 18: ...e tool with dovetail for fixing Connection to weight indicator by means of StarBus cable several lengths Connection to radio kit Remote displays LCD REM 40A numerical LCD with digits 40 mm high L 175 x H 130 x W 105 mm LED REM 40B numerical LED with digits 40 mm high L 175 x H 130 x W 105 mm LED REM 57 numerical LED with digits 57 mm high L 315 x H 130 x W 105 mm Indicator mod 700 710 16 ACCESSORI...

Page 19: ...dance with the essential requirements of the applicable directive 1 Electromagnetic Compatibility Directive 89 336 CEE modified by 92 31 CEE 93 68 CEE 93 97 CEE Applied harmonized law CEI EN 61326 Codogno 02 November 2004 The technical head Fabio Perin Denomination Weighing System 700 710 Model CE Declaration of conformity ...

Page 20: ...NOTES ...

Reviews: