Indicator mod. 700/710
9
PROGRAMMING PER NUMBER OF ANIMALS
e.g. - program recipe n. 2 for 123 animals with ingredient n. 1 of 1,10 kg, n. 2 of 2,25 kg, n.
3 of 9,20 kg and n. 4 of 0,72 kg.
The full stop (.) indicates that the values are expressed per animal.
Proceed as follow: switch the indicator on and wait for a few seconds
2
t
0
2
c
0000
2
c
0003
2
c
0003
2
c
0023
2
c
0023
2
c
0123
2
1
00.00
2
1
00.00
2
1
00.10
2
1
00.10
2
1
01.10
2
2
00.00
2
2
00.05
2
2
00.05
PRESS
DISPLAY
press it twice for the program function; the indicator sets
over PROGRAM.
The total of the recipe n. 1 will be displayed
it increases the number of the recipe
it confirms the recipe n. 2; it asks for the number
of animals (the right digit blinks)
it increases the first digit (units)
it memorizes the first digit and displays the second one
it increases the second digit (tens)
it memorizes the second digit
it increases the third digit (hundreds)
it memorizes the number of animals and displays
the value of the ingredient n. 1
it memorizes the first digit (dag)
it increases the value of the second digit (hg)
it memorizes the second digit
it increases the third digit (kg)
it memorizes the value of the ingredient n. 1 and displays
the value of the ingredient n. 2
it increases the first digit (dag)
it memorizes the first digit
1