Safety and approvals

 

● It is a legal requirement that the installa<on of this appliance is in accordance with Local Building Control Approval 

and is installed by a qualified/competent person. We strongly recommend that a qualified heating & plumbing engi-

neer carries out this work. HETAS Ltd operate such a scheme and a listing of their competent persons can be found on 

their website: 

www.hetas.co.uk

 

● The boiler should be located on a level non-combustible surface, with suitable load bearing capacity. 

 

● Allow sufficient room around the boiler for  maintenance and cleaning. 

 

● Ensure the customer is presented with this manual following installa<on. 

 

● Ensure the appliance is installed and maintained in accordance with these instruc<ons. Failure to do so may result in 

unsafe  operation,  and  will  invalidate  any  guarantee  or  warranty.  The  appliance  and  flue  should  be  inspected  and 

cleaned annually. More frequent cleaning may be required if unseasoned wood is used. Consult a qualified chimney 

sweep or heating engineer if in any doubt. 

 

● Improper use of this appliance can lead to injury or death of the user or third a party. Therefore, ensure the appli-

ance is installed in accordance with this manual and any rules in force. Any faults should be fixed immediately to en-

sure safe operation. The manufacturer accepts no responsibility for improper use and/or installation of this appliance. 

This includes maintaining the installation, operation and conditions specified by the manufacturer. 

Boiler Location Requirements and Safety Notes.

 

THESE  BOILERS  MUST  BE  INSTALLED  IN  ACCORDANCE  WITH  CURRENT  BUILDING  STANDARDS  AND  REGULATIONS 
AND ANY LOCAL BYE LAWS, BY A SUITABLY QUALIFIED/COMPETENT PERSON. 

Summary of Contents for MC 5.20 CI

Page 1: ...190171 H 122010 INSTALLATION AND USER INSTRUCTIONS M C S E R I E S L O G B O I L E R MC 5 20 CI 5 20 kW MC 5 30 CI PF 5 30 kW MC 5 30 CI GF 5 30 kW...

Page 2: ...US Boiler Identification 7 Boiler Specification 7 Boiler Appliance Contents 8 Boiler Dimensions 9 ASSEMBLY Boiler Assembly 10 SETUP AND USE Fitting and Calibration of the Thermostat 11 Use and Operati...

Page 3: ...ectrical work should be carried by a qualified electrician in accordance with the latest regulations Before attempting any work on the boiler or system controls ensure the mains supply is disconnected...

Page 4: ...do so may result in unsafe operation and will invalidate any guarantee or warranty The appliance and flue should be inspected and cleaned annually More frequent cleaning may be required if unseasoned...

Page 5: ...imum height of 600mm above the boiler to any bend is required taking into account that each bend will require an additional flue height to be provided Any bend should be no greater that 45 degrees IMP...

Page 6: ...per Chamber 3 designed to maximise efficiency by incorporating a series of water filled tubes through which flue gases pass Anti Boiling Quench Coil 4 to prevent overheating Fuelbed Grate Cleaning Doo...

Page 7: ...Miscellaneous 7 A Data Plate for each boiler is fitted to the top rear of the appliance beneath the top cover This is required when calling regarding a spares or technical enquiry Boiler Specifiation...

Page 8: ...s the main boiler combustion chamber engine unit which is shrink wrapped The following accessories are located within the boiler combustion chamber Box 3 Cardboard box containing the following compone...

Page 9: ...ht location for your boiler Locate your boiler so that you are able to easily access stored wood fuel Ensure there is sufficient access to load and clean the boiler Ensure the boiler is located in a d...

Page 10: ...10 Assembly Boiler assembly...

Page 11: ...C 50 C This can then be progres sively increased Cracking of the combustion chamber ceramic will occur this is normal and will not affected the operation of the boiler Position the control lever so t...

Page 12: ...f ash form the boiler and cleaning of the upper heat tubes and combustion chamber Periodic maintenance Ash removal and upper heat exchanger tube cleaning instruction Ash door rear spigot connection tw...

Reviews: