Operation
Prodigy/CME PC/104 User’s Guide
47
2
Settings & default values for Serial 1 and Serial 2:
To create a serial port peripheral connection, the above parameters are specified in the PRP action
Open
with the
resource set to
Device
. Messages to and from the Serial port are transmitted via the
Send
and
Receive
actions
sent to
the
Peripheral
resource. Whenever a new serial port peripheral is opened its previous function is canceled. By default
Serial 1 listens for PRP communications and Serial 2 is the console port.
After a reset or at power-up, the card retrieves default information for the serial ports. To change these default values,
the PRP action
Set
is send with a resource of
Device
2.6.3, “Setting Card Defaults,” on page
further.
For detailed information on PRP action formats and function, refer to the
Prodigy/CME Programmer’s Reference
.
2.5.2.1
Connections & associated signals
J17 comprises a special 10-pin dual header connector used to connect one or both serial ports. See Section
4.2.6, “Serial Connector,” on page
76 for a detailed signal description
of the Serial connector.
2.5.3
CANbus Communications
The Prodigy/CME PC/104 card provides a general purpose CANbus port compatible with the CAN 2.0B standard
which may be operated at various communication rates from 10,000 to 1,000,000 bps (bits per second). In addition,
each CANbus devices is assigned two CAN identifiers (also called a addresses); one for transmission of messages, and
one for reception of messages.
The following table summarizes this information along with the factory defaults for these values:
To create a CANbus peripheral conversation, the baud rate, send address and receive address are specified in the PRP
message body of an
Open
action sent to the
Device
resource. Messages to and from the CANbus port are transmitted
via the
Send
and
Receive
actions
sent to the
Peripheral
resource.
After a reset or at power-up, the card retrieves default information for the CANbus port. To change these default
values, the PRP
Set
action is used with a resource of
Device
. See Section
2.6.3, “Setting Card Defaults,” on page
for more information.
For detailed information on PRP action formats and function, refer to the
Prodigy/CME Programmer’s Reference
.
2.5.3.1
Connections & associated signals
J16 is an 8-pin dual header that comprises the CANbus network connection. See Section
77 for a detailed signal description of the CAN connectors.
Parameter
Range
Serial 1 Default
Serial 2 Default
Baud rate
1200 to 460,800
57,600
115,200
Parity
none, even, odd
none
none
# Data bits
5, 6, 7, 8
8
8
# stop bits
1, 2
1
1
Parameter
Range
Default
Baud rate
10,000 to 1,000,000 bps
1,000,000
Host send address
0 - 0x800
0x580
Host receive address
0 - 0x800
0x600
Summary of Contents for PR8358120
Page 6: ...vi Prodigy CME PC 104 User s Guide This page intentionally left blank ...
Page 8: ...viii Prodigy CME PC 104 User s Guide This page intentionally left blank ...
Page 56: ...Operation 56 Prodigy CME PC 104 User s Guide 2 This page intentionally left blank ...
Page 88: ...Electrical Reference 88 Prodigy CME PC 104 User s Guide 4 This page intentionally left blank ...
Page 98: ...Interconnect Module 98 Prodigy CME PC 104 User s Guide 5 This page intentionally left blank ...
Page 102: ...102 Prodigy CME PC 104 User s Guide This page intentionally left blank ...