Performance In Lighting A+ 100 Manual Download Page 3

3

3111435 | ED. 01 | 01 - 2021

ULTRANIK 

HF motion detector

B

For staircase and corridor (master and slave) 

SECTION 2 : REMOTE CONTROL

While the 1st sensor detects motion on the 1st floor, it switches the light on at 100% and sends signal to all 
slave units. All slaves on the 1st floor turn on and the sensor highbay on the 2nd floor switches on at 
stand-by level.

The person walks to the 2nd floor, the 2nd Sensor highbay switches the light on at 100%. All slaves on the 
2nd floor turn the light on and the Sensor highbay on the 3rd floor switches on at stand-by level.

10%

OFF

OFF

100%

100%

100%

OFF

OFF

OFF

OFF

OFF

OFF

MASTER

 SLAVE

CORRIDOR

100%

100%

100%

100%

100%

10%

OFF

OFF

OFF

OFF

OFF

CORRIDOR

MASTER

 SLAVE

The person walks to the 3rd floor, the 3rd sensor highbay switches the light on 100%. All slaves on the 3rd 
floor turn the light on and the Sensor highbay on the 4th floor switches onat stand-by level. Meanwhile, 
the lights on the 1st floor are dimmed to stand-by level after hold-time.

The person walks to the 4th floor, the 4th sensor highbay switches the light on at 100%. All slaves on the 
4th floor turn the light on Meanwhile, all sensors on the 1st floor turn the light off after stand-by period, 
and all lights on the 2nd floor dim to stand-by level after hold-time.

PERMANENT ON/OFF  

( button 

1

 )

Press button 

1

, to select permanent ON or permanent OFF mode.

* Press button 

2

 / 

4

 to resume automatic operation.

The mode will change to AUTO Mode after power failure.

RESET  

( button 

2

 )

Press button 

2

, all settings go back to the default settings : 

Detection range: 100%      Hold time: 1min      Stand-by period: 5min      Stand-by dimming level: 20%      Daylight sensor: LUX disable

SHIFT 

( button 

3

 )

Press button 

3

, the LED on the top left corner will flash to indicate mode selection. All values / settings in RED are valid for 20 seconds.

AUTO MODE  

( button 

4

 )

Press button 

4

, to initiate automatic mode. The sensor starts working and all settings remain as before the light was switched ON/OFF.

SEMI-AUTO MODE  

( button 

4

)

1. Press button 

Shift (the red LED is on for indication)

2. Press button 

to initiate semi-auto mode. The fixture is manually on by push-switch and  automatically off in semi-auto mode.

POWER OUTPUT   

( button 

5

 )

Press button 

5

, the light output shifts between 80% and 100%. 

Note: the function of “Sensor off” and “Twilight” are disabled. 

BRIG/-   

( button 

6

 )

Press button 

 to adjust the light brightness between 10%~100% .

SCENE PROGRAM  

( zone 

7

 ) (One-key-commissioning)

1. Press button “start” to program.
2. Select the buttons in 

“Detection range”, 

/

 10

  “Daylight hreshold”, 

11

 “Hold time”, 

12 

“Stand-by time”, 

13 

“Stand-by dimming 

level” to set all parameters.
3. Press button “Memory” to save all the settings programmed in the remote control.
4. Press button “Apply” to set the settings to each sensor unit(s). For example, to pre-set detection range 100%, daylight threshold Disable, 
hold time  5min, stand-by time +∞, stand-by dimming level 30%, the steps should be as follows: Press button 

Start,  button 

100%, 

10 

Disable, 

Shift,  

11 

5min, 

Shift, 

12 

+∞, 

13 

30%, 

Memory. By pointing to the sensor unit(s) and pressing 

Apply, all 

settings are passed on the sensor(s).           

1

3

100%

100%

10%

10%

10%

100%

100%

100%

10%

OFF

OFF

CORRIDOR

MASTER

 SLAVE

10%

10%

10%

OFF

OFF

OFF

100%

100%

100%

100%

100%

CORRIDOR

MASTER

 SLAVE

HRC-11

Note: the red LED indicator flash one time when RC 
receives signal successfully

7

3

1

6

5

2

4

4

2

Summary of Contents for A+ 100

Page 1: ...svar for PERFORMANCE iN LIGHTING S p A Reproduktion også kun delvis er forbudt uden skriftlig tilladelse fra PERFORMANCE iN LIGHTING S p A CZ DŮLEŽITÉ Pro zajištění správné činnosti a bezpečnosti zařízení je nutné aby instalaci provedl odborným způsobem kvalifikovaný personál který dodržuje dále uvedené pokyny Před každou údržbou vždy vypněte napětí pomocí dvoupólového vypínače Pokyny se musí ulož...

Page 2: ...matically on when needed and dimmed to preset level before it is totally off The light keeps off during daytime even when movement is detected Ambient lux level is above preset daylight threshold With movement and insufficien tambient lux level the light is triggered on 100 by the detector The light turns off automatically after stand by time If there is no more movement the light dims to stand by...

Page 3: ...e 1min Stand by period 5min Stand by dimming level 20 Daylight sensor LUX disable SHIFT button 3 Press button 3 the LED on the top left corner will flash to indicate mode selection All values settings in RED are valid for 20 seconds AUTO MODE button 4 Press button 4 to initiate automatic mode The sensor starts working and all settings remain as before the light was switched ON OFF SEMI AUTO MODE b...

Page 4: ...es signalsuccessfully 14 9 13 12 11 10 8 MALFUNCTIONCAUSE REMEDY CAUSE REMEDY The fixture does not light up The fixture is always on The fixture is on when it should not Incorrect daylight threshold setting Continuos movement in the detection zone Sudden change in temperature due to weather wind rain snow or air expelled from fans or open windows Faulty fixture No power supply Adjust daylight thre...

Page 5: ...2 V WHITE BLACK GND 3x 0 75 1 5 mm2 Ø5 8 mm 14 16 mm 4 6 mm 3 PIN POWER SOCKET PLUG 1 10V WIRING GND 12V 0 10V 3 2 8 3 7 Nm CONNECT MAIN VOLTAGE CLOSE 2x 4 DISCONNECT MAIN VOLTAGE OPEN 2x DA1 DALI 2 DALI 1 DA2 2x 0 75 1 5 mm2 Ø5 8 mm 14 16 mm 4 6 mm 2 PIN POWER SOCKET PLUG DA2 DA1 1 2 DALI WIRING 2 8 3 7 Nm CONNECT MAIN VOLTAGE CLOSE 2x 3 ...

Page 6: ...d the light will recover to the state before power failure In push dimming mode the dimming direction of each pressing is the opposite of the previous direction OPERATION LASTING TIME FUNCTION 0 1 0 5 S 0 6 5 S 9 S LED light on off Dim up down Reset to 50 luminance of push setting SHORT PRESS LONG PRESS RESET PRESS Instruction of Push Dimming Wiring diagram of Push Dimming LED AC L AC N DA1 PUSH D...

Page 7: ... hazards Man made damage is not covered by warranty ATTENTION The default setting is 10V the maximum output Connect the DALI signal to DA1 and DA2 terminals The DALI protocol includes 16 groups and 64 IP addresses The minimum dimming depth of the DALI dimming is 10 The DALI dimming function and push dimming function cannot be used at the same time otherwise the DALI dimmer will be damaged Instruct...

Page 8: ...ור מפזר הזכוכית לניקוי ﺑﺼﻮرة اﻟﻔﺎﻧﻮس ﻧﺎﺷﺮة زﺟﺎج ﺗﻨﻈﻴﻒ ﺮﺟﻰ ُ ﻳ SA ﺗﺴﺘﺨﺪم ﻻ D ﻧﺎﻋﻤﺔ ﻗﻤﺎش ﻗﻄﻌﺔ ﺑﺎﺳﺘﺨﺪام ﻣﻨﺘﻈﻤﺔ اﻹﺿﺎءة ﻣﻮزع اﻟﺰﺟﺎج ﺗﻨﻈﻴﻒ ﻓﻲ اﻟﻜﻴﻤﻴﺎﺋﻴﺔ اﻟﻤﻮاد IT Per preservare l ambiente a fine vita non gettare questo apparecchio nella normale raccolta dei rifiuti ma portarlo in uno dei punti di raccolta autorizzati EN In respect and compliance to environmental standars at the end of life do not dispo...

Reviews: