Sensor Adjustments Console:

Setstheinfraredrange

Rangesetting
FullCCW=min.(OFF)
FullCW=max.

Passive Infrared Adjustment

Delayed-OFFtime

Daylight Sensor Adjustment

Factory  default  setting  is  disabled.  If  installed
location calls for the use of daylight sensor this is
the  adjustment  for  control  of  required  ambient
light levels necessary to disable the automatic
ON control of the sensor when detecting occu -
pancy. NOTE: The daylight sensor function is not
applicable in rooms using manual ON control.

All aspects of sensor operation can be adjusted here.
View  of  adjustments  when  cover  is  removed.  Dip
Switch  setting  table  below  illustrates  how  to  enable
and disable sensor functions.

Each  time  motion  is  detected,  the  lights  remain
activated  for  a  pre-set  time,  which  is  set  by  the
Off-time adjustment. The fully counter-clockwise
setting  (30seconds)  can  be  used  for  testing.  If
motion is detected during the ON time, the timer
resets  and  lights  will  remain  on  until  the  full

PIR sensitivity can be dialed up or down to meet
the  exact  needs  of  any space. This  adjustment  is
helpful  to  ensure  detection  in  all  areas  during  a
walk test.

Setstheultrasonicrange

Rangesetting
FullCCW=min.(OFF)
FullCW=max.

Ultrasonic Adjustment

Ultrasonic sensitivity can be dialed up or down to
meet  the  exact  needs  of  any space.  This  adjust-
ment  is  helpful  to  ensure  detection  in  all  areas
during a walk test.

SWITCHFUNCTIONS
BankAOFFON

Single  Multi  Tech  Mode  Multi  Tech 

Single  Tech

/--

Single Tech (A1 ON) 

PIR 

Ultrasonic

Walk  Through  Mode 

Walk  Through  Enable  Walk  Through  Disable

---

BankB

Light  Mode 

L i g hts  Adjust Enable 

Lights  Adjust Disable

LEDs  Mode 

LEDs Enabled 

LEDs  Disable

Test  Mode 

OFF 

ON 

OFF = Enter/Exit Test  Mode

N/A 

N/A 

N/A

SWITCHSETTINGS

SWITCH

A1

A2

*

A3
A4

B1
B2
B3
B4

Multi-Tech (A1 OFF) 

Multi

-

Tech mode1 

Multi

-

Tech mode2

DIP SWITCH SETTINGS

N/A 

N/A 

N/A

Summary of Contents for PS-PCL24-R

Page 1: ...able is active in this mode Motion detection by the selected technology will turn ON the lights as well as keep them ON When motion is not detected the lights will turn OFF after the delayed off time Multi tech Mode Mode 1 Switch A1 is OFF and Switch A2 is OFF PIR detection will turn lights ON in this mode motion detection by either technology will keep the lights ON If neither technology detects ...

Page 2: ...ch is set by the Off time adjustment The fully counter clockwise setting 30seconds can be used for testing If motion is detected during the ON time the timer resets and lights will remain on until the full PIR sensitivity can be dialed up or down to meet the exact needs of any space This adjustment is helpful to ensure detection in all areas during a walk test Setstheultrasonicrange Rangesetting F...

Page 3: ...Note Sensor tested using NEMA WD 7 2011 Occupancy Motion Sensors Standard ...

Page 4: ...tical view patterns An ellipse shape detection coverage not full circle Detect movement 40 degree across optical zone Sensor Technology Comparison HDIR technology significantly surpasses known boundaries of IR sensor technology Extending the capability of IR to new levels of accuracy through a combination of patented sensor hardware and logic algorithms The power behind this innova tion originates...

Page 5: ...dles FC level inhibiting the lights from turning ON LED Operation The Sensor has two LED indicators that when enabled will has been detected by Infrared Technology Green indicates Ultrasonic TOP VIEW Field of view intersection with floor Top view in feet 9 foot mounting height 0 20 12 4 0 8 16 4 12 20 16 8 10 10 Minor Motion Detection ft Detection range estimation Example for 8 ft height Major mot...

Page 6: ...oltage Wires Wallboard Ceiling Sensor Base Ring Sensor Base Mounting Screws 2 places Sensor Front Cover Mounting Anchors 1 cut 2 hole in ceiling 2 mount sensor 2 in 5 2 3 4 Included Parts List Sensor 1 Base mounting ring 1 Wall Anchors 3 Spring mounting clip 2 PIR detection Mask 1 7 8 Wall anchor screw 3 Tools required for install Slotted Phillips Screwdriver Wire Stripper Pencil Wire Cutters Hole...

Page 7: ...tical view patterns An ellipse shape detection coverage not full circle Detect movement 40 degree across optical zone Sensor Technology Comparison HDIR technology significantly surpasses known boundaries of IR sensor technology Extending the capability of IR to new levels of accuracy through a combination of patented sensor hardware and logic algorithms The power behind this innova tion originates...

Reviews: