PerfectEnergy PEM-160/X-72M Installation Manual Download Page 3

Installation Manual             

 

Last revised: January 2011

         

The technical specifications are subject to change without notice

 

page 3

 

3.

 

Safety instructions 

 

 

The assembly and commissioning of the solar modules may only be carried out by those, who are 
qualified to correctly and safely install the system. 

 

Pay attention to the local ordinances, building standards and accident-prevention regulations. 

 

The safety information for other system components must also be followed. 

 

Do not install or handle the modules when they are wet or during periods of high wind. 

 

Use suitable fall-protection equipment. 

 

Secure work materials to prevent articles from falling. 

 

Secure the working area to avoid accidents with other people. 

 

Never install damaged solar modules! 
Before installing, check the junction-box, cables and socket connectors for damages. 

 

Never use the junction-box or the solar cable to carry the unit. 

 

Do not apply paint or any adhesives to the rear side of the solar module. 

 

Do not allow any objects to fall upon the solar module. 

 

Avoid scratches to the front glass. 

 

Do not walk across or step on the solar module! 

 

If the front glass is broken, or the backsheet is torn, contact with any module surface or module 
frame can cause electric shock. 

 

Cover all modules in the PV array with an opaque cloth or material before making or breaking 
electrical connections. 

 

Electrical commissioning of the solar modules may only be carried out by a professional installer! 

 

Do not connect or disconnect modules when current from the modules or an external source is 
present. 

 

Remove all metallic jewelry prior to installing this product to reduce the chance of accidental 
exposure to live circuits. 

 

Only use dry, insulated tools for the electrical assembly work. 

 

Ensure that the cable connections are in perfect condition (no cracking, soiling or other 
contamination). 

 

Pay attention to the inverter manufacturer’s installation instructions! 

 

Before starting work on a PV-system, switch it off with a disconnection switch. Working with 
conductors, which conduct direct current can cause electric arcs! 

 

When installed on a roof, the module shall be mounted over a fire-resistant roof covering rated for 
the application. Solar modules are considered as „non-explosion-protected-equipment“. Hence, 
they must neither be installed near highly flammable gases and vapors (e.g. filling stations, gas 
containers, paint spraying equipment), nor near open flames or flammable materials. 
 
 
 
 
 
 

Summary of Contents for PEM-160/X-72M

Page 1: ...les by Perfectenergy in outdoor open spaces fields or on flat or tilted roofs They are only for specialists who are familiar with the installation due to their vocational qualification and they contain safety relevant instructions for the assembly connection and maintenance of the solar modules Important Notice The installation of the solar modules and especially the electrical installation may on...

Page 2: ...e more current and or voltage than reported at standard test conditions Sunny cool weather and reflection from snow or water can increase current and power output Accordingly the values of Isc and Voc marked on this module should be multiplied by a factor of 1 25 when determining component voltage ratings conductor current ratings fuse sizes and size of controls connected to the PV output Our prod...

Page 3: ...glass is broken or the backsheet is torn contact with any module surface or module frame can cause electric shock Cover all modules in the PV array with an opaque cloth or material before making or breaking electrical connections Electrical commissioning of the solar modules may only be carried out by a professional installer Do not connect or disconnect modules when current from the modules or an...

Page 4: ...ast 500m from the sea and sulfur sulfur sources volcanoes The modules may not be exposed to extremely corrosive chemicals e g emissions from manufacturing plants When installed on a roof the module shall be mounted over a fire resistant roof covering rated for the application 4 2Instructions for mounting Assembly work may only be performed by trained and qualified personnel Fasten modules firmly t...

Page 5: ...gn strength of 5400 Pa corresponds approximately to a wind speed of 500 Km h 300 mph PEM 160 X 72M PEM 180 X 72M SCC Screw attachment Secure the module to the structure using the factory mounting holes Four M8 stainless steel bolts with nuts washers and lock washers are recommended per module Refer to the drawing on the right for the module dimensions and mounting hole locations Clamps admissible ...

Page 6: ...resistant cable ties to avoid the pin and socket connections being at a water settlement level The junction boxes are equipped with 3 bypass diodes In the event of clouding these minimize the losses and help to prevent damage to the solar modules When connecting the solar modules to an inverter please observe the information provided by the manufacturer of the inverter 6 Grounding The company inst...

Page 7: ...ng materials such as scouring powder steel wool scrapers blades or other sharp instruments to clean the glass surface of the module Use of such materials will invalidate the product warranty The PV system should be inspected once a year with regard to the following Secure hold and no rust on any of the attachments Secure connection cleanliness and that all cable connections are free of corrosion S...

Reviews: