Technical Data

 

   The power output is subject to a manufacturing tolerance of ± 3%. 
   The dimensions are subject to a manufacturing tolerance of ± 2 mm. 
   The technical specifications are subject to change without notice. 

 
 
General:  
 

 

Solar modules generate electricity as soon as they are exposed to light. The voltage of a single module 
is less than 50VDC. If several modules are connected in series, the voltages of the individual modules 
accumulate and can pose a hazard. 

 

The modules are qualified for application class A: Hazardous voltage (IEC 61730: > 50V; EN61730: 
>120V), hazardous power applications (>240W), where general contact access is anticipated.  
Modules qualified for safety through EN 61730-1 and -2 within this application class are considered to 
meet the requirements of Safety Class II. 

 

The maximum system voltage of solar modules connected to each other may not exceed 1000 VDC. 

 

Under normal conditions, a photovoltaic module is likely to experience conditions that produce more 
current and/or voltage than reported at standard test conditions. Sunny, cool weather and reflection 
from snow or water can increase current and power output. Accordingly, the values of Isc and Voc 
marked on this module should be multiplied by a factor of 1.25 when determining component voltage 
ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV-output. 

 

Our products are not intended for use where artificially concentrated sunlight is applied to the 
module. 

 
 
 

Type designation 

PEM-160/X-72M

 

PEM-180/X-72M-SCC

 

Electrical Data

 

(rated at Standard Test Conditions: Irradiance 1000 W/m²; Air mass 1.5; Temperature 25°C)

 

Nominal Power (P) 

170 W 

175 W 

180 W 

180W 

185W 

190W 

Mpp-Voltage (Vmpp) 

35,6 V 

35,9 V 

36,3 V 

36,4 V 

36,7 V 

36,9 V 

Open Circuit Voltage (Voc) 

44,3 V 

44,6 V 

44,7 V 

44,8 V 

45,0 V 

45,4 V 

Mpp-Current (Impp) 

4,77 A 

4,88 A 

4,95 A 

4,95 A 

5,05 A 

5,16 A 

Short-circuit-current (Isc) 

5,12 A 

5,20 A 

5,28 A 

5,29 A 

5,37 A 

5,51 A 

Maximum over-current 

10 A 

10 A 

Temperature coefficients [%/°C] 

Power (αP) 

-0,49 

-0,49 

-0,49 

-0,49 

-0,49 

-0,49 

Open Circuit Voltage (αVoc) 

-0,34 

-0,34 

-0,34 

-0,34 

-0,34 

-0,34 

Short-circuit-current (αIsc) 

+0,03 

+0,03 

+0,03 

+0,03 

+0,03 

+0,03 

Mechanical Data 

Measurements 

1580 x 808 x 45 mm 

1580 x 808 x 45 mm 

Weight 

15,5 Kg 

15,5 Kg 

Maximum load 

5400 Pa 

5400 Pa 

Summary of Contents for PEM-160/X-72M

Page 1: ...les by Perfectenergy in outdoor open spaces fields or on flat or tilted roofs They are only for specialists who are familiar with the installation due to their vocational qualification and they contain safety relevant instructions for the assembly connection and maintenance of the solar modules Important Notice The installation of the solar modules and especially the electrical installation may on...

Page 2: ...e more current and or voltage than reported at standard test conditions Sunny cool weather and reflection from snow or water can increase current and power output Accordingly the values of Isc and Voc marked on this module should be multiplied by a factor of 1 25 when determining component voltage ratings conductor current ratings fuse sizes and size of controls connected to the PV output Our prod...

Page 3: ...glass is broken or the backsheet is torn contact with any module surface or module frame can cause electric shock Cover all modules in the PV array with an opaque cloth or material before making or breaking electrical connections Electrical commissioning of the solar modules may only be carried out by a professional installer Do not connect or disconnect modules when current from the modules or an...

Page 4: ...ast 500m from the sea and sulfur sulfur sources volcanoes The modules may not be exposed to extremely corrosive chemicals e g emissions from manufacturing plants When installed on a roof the module shall be mounted over a fire resistant roof covering rated for the application 4 2Instructions for mounting Assembly work may only be performed by trained and qualified personnel Fasten modules firmly t...

Page 5: ...gn strength of 5400 Pa corresponds approximately to a wind speed of 500 Km h 300 mph PEM 160 X 72M PEM 180 X 72M SCC Screw attachment Secure the module to the structure using the factory mounting holes Four M8 stainless steel bolts with nuts washers and lock washers are recommended per module Refer to the drawing on the right for the module dimensions and mounting hole locations Clamps admissible ...

Page 6: ...resistant cable ties to avoid the pin and socket connections being at a water settlement level The junction boxes are equipped with 3 bypass diodes In the event of clouding these minimize the losses and help to prevent damage to the solar modules When connecting the solar modules to an inverter please observe the information provided by the manufacturer of the inverter 6 Grounding The company inst...

Page 7: ...ng materials such as scouring powder steel wool scrapers blades or other sharp instruments to clean the glass surface of the module Use of such materials will invalidate the product warranty The PV system should be inspected once a year with regard to the following Secure hold and no rust on any of the attachments Secure connection cleanliness and that all cable connections are free of corrosion S...