5). Disconnect the charge hose from the vacuum
pump.
2. Refrigerant charging
Procedure:
1). Connect the charge hose to the charging
cylinder, open the 2-way valve and the 3-way
valve.
Connect the charge hose which you disconnected
from the vacuum pump to the valve at the bottom
of the cylinder. If the refrigerant is R410A, make
the cylinder bottom up to ensure liquid charge.
2). Purge the air from the charge hose
Open the valve at the bottom of the cylinder and
press the check valve on the charge set to purge
the air (be careful of the liquid refrigerant).
3) Put the charging cylinder onto the electronic
scale and record the weight.
4). Open the valves (Low side) on the charge set
and charge the system with liquid refrigerant
If the system cannot be charge with the specified
amount of refrigerant, or can be charged with a
little at a time (approximately 150g each time) ,
operating the air conditioner in the cooling cycle;
however, one time is not sufficient, wait
approximately 1 minute and then repeat the
procedure.
5).When the electronic scale displays the proper
weight, disconnect the charge hose from the 3-
way valve’s service port immediately
If the system has been charged with liquid
refrigerant while operating the air conditioner, turn
off the air conditioner before disconnecting the
hose.
6). Mounted the valve stem caps and the service
port. Use torque wrench to tighten the service
port cap to a torque of 18N·m (13.27 ft·lbs).
Always leak check after servicing the refrigerant
system.
For M5OC-48HFN1-M
There are one low-pressure centralized valve and
one high-pressure centralized valve, it will be
more time saving when vacuum and recycle
refrigerant. But refer to the previous instruction
when vacuum and recycle refrigerant.
6. Electronic Function
6.1 Abbreviation
T1: Indoor ambient temperature
T2: Coil temperature of indoor heat exchanger
middle.
T2B: Coil temperature of indoor heat exchanger
outlet. (This sensor is located in the outdoor unit)
T3: Pipe temperature of outdoor heat exchanger
T4: Outdoor ambient temperature
T5: Compressor discharge temperature
6.2 Electric control working environment.
6.2.1 Input voltage: 230V.
6.2.2 Input power frequency: 60Hz.
6.2.3 Indoor fan normal working amp. is less than
1A.
6.2.4 Outdoor fan. Normal working amp. is less
than 1.5A.
6.2.5 Four-way valve normal working amp. is less
than 1A.
Summary of Contents for 1PAMSH18-MZO2-16
Page 3: ... Model 1PAMSH27 MZO3 16 W210 metal plate 113 Model 1PAMSH36 MZO4 16 W520 metal plate 128 ...
Page 6: ...2 Suggested Indoor Unit Model Numbers ...
Page 7: ......
Page 9: ......
Page 23: ...7 Wiring Diagrams 8 1 Wiring diagram of 1 drive 2 outdoor 1PAMSH18 MZO2 16 ...
Page 24: ...PCB board of 1PAMSH18 MZ O2 16 ...
Page 25: ...IPM board of 1PAMSH18 MZO2 16 ...
Page 26: ......
Page 27: ...8 2 Wiring diagram of 1 drive 3 outdoor 1PAMSH27 MZO3 16 ...
Page 28: ......
Page 29: ......
Page 30: ...PCB board of 1PAMSH27 MZO3 16 ...
Page 31: ...IPM board of 1PAMSH27 MZO3 16 ...
Page 32: ...8 3 Wiring diagram of 1 drive 4 outdoor 1PAMSH36 MZO4 16 ...
Page 33: ...PCB board of 1PAMSH36 MZO4 16 ...
Page 34: ...IPM board of 1PAMSH36 MZO4 16 ...
Page 35: ...PFC board of 1PAMSH36 MZO4 16 ...
Page 36: ...8 4 Wiring diagram of 1 drive 5 outdoor ...
Page 37: ......
Page 71: ...IPM for dual tri zone IPM for qua zone P N for dual tri zone ...
Page 72: ...P N for qua zone ...
Page 73: ...bridge rectifier for dual tri zone bridge rectifier for qua zone ...
Page 74: ...Remark Measure the DC voltage between and port The normal value should be 190V 250V ...
Page 76: ...Two ports of the inductance Inductance ...
Page 77: ......
Page 80: ...Vsp FG ...
Page 82: ......
Page 85: ......
Page 88: ......
Page 90: ......
Page 103: ...6 EXV check Disconnect the connectors ...
Page 105: ...Red Blue Red Yellow ...
Page 106: ...Brown Orange Brown White ...
Page 121: ...Screws of front panel Screws of right rear panel Screws of top cover ...
Page 136: ...Screws of front panel Screws of big handle Screws of right rear panel ...