Perfect Aire PAWM1 User Manual Download Page 4

SAFETY GUIDELINES 

To reduce the risk of electrical shock, this product has a polarized plug (one blade is wider than 

the other). As a safety feature this plug will fit into the outlet only one way. If the plug does not fit 

fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT 

attempt to bypass this safety feature. Improper use of electric cords and plugs can cause a fire or 

electric shock hazard. NEVER pull on the cord to remove the plug from the outlet. Grip plug and 

pull from outlet. Check the power cord and plug for damage. A damaged cord or plug must be 

repaired before using the humidifier.

DANGER!

When using electrical appliances, basic safety precautions should always be followed. Doing so 

will reduce the risk of fire, electrical shock, and injury to persons. Please adhere to the following 

safety instructions:
1.  The unit should always be placed on a firm, flat, waterproof surface at least 4 ft away from 

the bedside, 12 in. from the wall and out of reach of patients, children and pets.

2.  The unit should not be left unattended in a closed room as air can become saturated and 

result in condensation on walls and furniture. Always leave room door at least partially open.

3.  Before using the unit, extend the cord and inspect it for any signs of damage. DO NOT use 

the unit if the cord has been damaged.

4.  To avoid fire or shock hazard, plug the appliance directly into a 110-120V AC electrical outlet.
5.  The unit should always be unplugged and emptied when not in operation or while being 

cleaned. Shut off and unplug the appliance before moving it. DO NOT move or tilt unit while 

it is in operation. Plug and unplug humidifier with dry hands. NEVER pull by cord.

6.  DO NOT operate the unit without water in the tank. Turn off and unplug the unit when the 

tank is empty and the refill light is on.

7.  CAUTION: DO NOT use an extension cord. Doing so can result in fire, shock, or 

personal injury.

8.  Unit requires regular cleaning. See cleaning instructions in this manual.
9.  DO NOT operate the unit outdoors. It is intended for indoor use only.
10.  DO NOT cover or insert objects into any openings on the unit.
11.  DO NOT attempt to repair or adjust any electrical or mechanical functions on the unit as 

doing so will void your warranty and may result in injury.

12.  DO NOT add any medications into the chimney, base, reservoir or water tank (only in the 

medicine cup.)

13.  DO NOT touch the steam vapor. Steam can cause burns. Do not operate without the 

medicine cup in place on top of the mist chimney.

14.  When moving or lifting the tank, use one hand on the tank handle and the other on the 

bottom of the tank.

15.  The unit is for residential use only.

2

Summary of Contents for PAWM1

Page 1: ......

Page 2: ...INSIDE FRONT COVER BLANK ...

Page 3: ...Technical Data 3 Operating Instructions Setting Up Your Humidifier 4 Filling Refilling Your Humidifier 4 How to use Your Humidifier 5 Using Liquid Inhalant 5 Night Light 6 Weekly Cleaning Care 6 7 Storage Instructions 8 Warranty 8 Troubleshooting 9 1 ...

Page 4: ...g the unit extend the cord and inspect it for any signs of damage DO NOT use the unit if the cord has been damaged 4 To avoid fire or shock hazard plug the appliance directly into a 110 120V AC electrical outlet 5 The unit should always be unplugged and emptied when not in operation or while being cleaned Shut off and unplug the appliance before moving it DO NOT move or tilt unit while it is in op...

Page 5: ...n output setting Output per Day 1 9 gal day max Output per Hour 10 1 oz hr max Electrical Rating 110 120V 60 Hz Power 260W STRUCTURE DIAGRAM Pictures for reference only Your warm mist humidifier is designed to provide visible warm moisture The humidifier tank delivers water into the boiling chamber where it is heated until it produces a steam vapor The steam vapor mixes with dry air in the mist ch...

Page 6: ...his product produces HOT STEAM and should be placed in an area not accessible to children or pets ensuring that the power cord is securely out of reach FILLING REFILLING YOUR HUMIDIFIER NOTE When moving or lifting the tank use one hand on the tank handle and the other on the bottom of the tank 1 Remove tank by grasping handle and gently pulling up Remove tank cap located on bottom of tank by turni...

Page 7: ...n use or for at least 20 30 minutes after unit has been turned off and unplugged When moving the humidifier turn it off unplug it and wait 20 30 minutes before moving it Never operate the humidifier without the tank in place Never attempt to operate the unit if the humidifier tank is empty Do not attempt to operate your humidifier without the mist chimney removable tray and medicine cup properly a...

Page 8: ...at temperatures below 158 F 70 C See Fig 5 below Run the dishwasher on the light duty or normal cycle Do not wash with soiled articles dishes DO NOT USE DETERGENTS If you use your dishwasher you will not need to follow the disinfecting and scaling procedures described on the following pages Please Note Do not place parts on lower rack of dishwasher Doing so could cause damage to the humidifier par...

Page 9: ...rasives on the heating element Doing so will damage the heating element Rinse tank base mist chimney removable tray and medicine cup until smell of the solution is gone CAUTION DO NOT IMMERSE BASE IN WATER 8 Next disinfect the unit by following the instructions below How to Disinfect Following Removal of Scaling 1 Pour 1 teaspoon of bleach into the tank 2 Fill the remainder of the tank with water ...

Page 10: ...nt in water Damage to product walls paintings portraits any furniture wood floors etc as a result of improper installation and or cleaning Use of improper voltage or current Additional or extended warranties offered by retailers Disassembly or repair by anyone other than an authorized Perfect Aire service center provider Products used in a commercial setting Floor display as is models Damage cause...

Page 11: ... was washed with detergent Rinse thorougly with clean water Reset light is illuminated Water tank is empty Refill water tank Unit not reset after refill Follow reset procedure on page 4 Water overflows from reservoir Tank may be leaking Check the tank for leaks and replace if necessary Tank cap is not tight Tighten tank cap Do not overtighten Condensation forms around humidifier or windows Mist intens...

Page 12: ...Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in China www perfectaire us 877 365 6274 Distributed by ...

Reviews: