background image

Perfect Aire, LLC
5401 Dansher Road
Countryside, IL 60625

Distributed by:

844-4PA-AIRE  |  844-472-2473

www.perfectaire.us

WINDOW

AIR CONDITIONER

FOR MODEL: 

6PAC10000
6PAC12000

Before using your air conditioner, please 
read this manual carefully and keep it for 
future reference, along with your receipt.

Specification and performance data is subject to change without notice.

Printed in China

PA/User6PAC10000_6PAC12000/12272018

USER MANUAL

Summary of Contents for 6PAC10000

Page 1: ...WINDOW AIR CONDITIONER FOR MODEL 6PAC10000 6PAC12000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL ...

Page 2: ...____________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installation Co _______________________________________ Installer Name ______________________________________ Installer Phone No ____________________________________ CONSUMER PRODUCT INFORMATION ...

Page 3: ...for installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be supervised to ensure that they do not play with the air conditioner Disabled persons may require assistance with set up If the power cord is to be replaced replacement work should be performed by authorized personnel only Installation and repai...

Page 4: ...m the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so may cause electric shock DO NOT use firearms near unit Doing so may cause fire DO NOT use the power cord close to heating appliances Doing so may cause fire and electric shock DO NOT disassemble modif...

Page 5: ...od of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or accident Periodically check installation bracket for damage Prolonged exposure to outdoor elements may cause damage to installation bracket causing unit to fall Always insert filter s securely Clean...

Page 6: ...e sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils WARNING ELECTRICAL INFORMATION The complete electrical rating of your new room air conditio...

Page 7: ...r is designed to install in standard double hung windows with opening widths of 23 to 36 inches 584 mm to 914 mm NOTE H vertical opening See table below TABLE 1 Model 5000 8000 Btu h 10000 12000 Btu h Size H 14 356 mm 15 394 mm CAUTION Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of the air conditioner Aluminum hou...

Page 8: ...Energy Star rated units only TOP RAIL HARDWARE 3 8 Screws 4 pcs Top Rail 1 pc Insulation Panels 2 pcs C Align the hole in the top rail with those in the top of the unit as shown in Fig B D Secure the top rail to the unit with the 3 8 screws as shown in Fig C STEP 3 INSTALL THE ACCORDION PANELS NOTE Top rail and accordion panels on each side are offset to provide the proper pitch of 5 16 to the rea...

Page 9: ...ely H Fig 5 above tilted about 3 to 4 downward to the outside If after proper installation condensation does not drain from the overflow drain hole during normal use adjust slope B Extend the accordion panels out against the window frame Fig 6 STEP 5 INSTALL SUPPORT BRACKET A Place the frame lock between the frame accordion panels and the window sill as shown in Fig 7 Drive 3 4 19 mm or 1 2 12 7 m...

Page 10: ...ese instructions STEP 6 1 After the unit is installed in the window measure the inner width of one of the accordion panels as shown in Fig 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 STEP 6 2 Mark a line on one of the provided insulation panels matching the measured width in Step 6 1 Cut the insulation panel along the line Fig 12 or STEP 6 3 Slide the insulation panel you just cut int...

Page 11: ...drain holes or slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out REMOVING AC FROM WINDOW Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety sash lock Remove screws installed through frame and frame lock Remove the Insulation Panels and close slide side accordion panels into frame Keeping a firm grip...

Page 12: ...follow the symbol for the functions you desire BEFORE operating the unit This unit can be controlled by the unit control or the remote control TIMER ECO MODE FILTER On Off Auto Cool Dry Fan Auto Low Med High FAN SLEEP Follow Me FOLLOW ME Indicator Energy Saver Mode Sets Mode Sleep Mode Turns Unit On or Off Set Fan Speed Adjusts Temp or Time Adjusts Temp or Time Remote Signal Receptor Check Filter ...

Page 13: ...illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and AUTO only AUTO COOLING and AUTO FAN modes TO OPERATE AUTO FEATURE When you set the air conditioner to AUTO mode it will automatically select cooling or fan only operation depending on what temperature you have selected and the room temperature The air conditioner wi...

Page 14: ...ht throughout the room as needed Pivot horizontal louvers until the desired vertical up down direction is obtained Move the levers from side to side until the desired horizontal left right direction is obtained ADDITIONAL THINGS YOU SHOULD KNOW The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and poss...

Page 15: ...placing As an alternative to washing the filter vacuum the filter clean NOTE Never use hot water over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mil...

Page 16: ...the coil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the room Remove grille and make sure the temperature sensor is not too close to the coils These two elements should not be touching Carefully straighten tube away from coil Make sure nothing is blocking the...

Page 17: ......

Page 18: ......

Page 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Page 20: ...01 Dansher Road Countryside IL 60625 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User6PAC10000_6PAC12000 12272018 ...

Reviews: