PROTECTION
(Continued)
31
OPERATING CONDITION
FEATURES OF PROTECTOR
FEATURES OF HEATING MODE
Operating Temperatures
TEMPERATURE
COOLING OPERATION
HEATING OPERATION
DRYING OPERATION
Indoor Temperature
max
89.6°F (32°C)
80.6°F (27°C)
89.6°F (32°C)
min
69.8°F (32°C)
44.6°F (7°C)
64.4°F (18°C)
Outdoor Temperature
max
109.4°F (43°C)
75.2°F (24°C)
109.4°F (43°C)
min
14℉(-10℃)
-13℉(-25℃)
69.8°F (21°C)
The protective device will work in the following circumstances:
• Wait 3 minutes before restarting operation after the unit stops, or when changing modes.
• Connect to power supply and turn on the unit at once, it may start 20 seconds later.
If all operation has stopped, press ON/OFF button again to restart, Timer should be set again as if it has
been canceled.
PREHEAT
At the beginning of the HEATING operation, the airflow from the indoor unit will be discharged in 2-5 minutes.
DEFROST
In HEATING operation, the appliance will defrost (de-ice) automatically to raise efficiency. This procedure
usually lasts 2-10 minutes. During defrost, fans stop operation. After defrost completes, it returns to HEATING
mode automatically.
NOTE:
• Optimum performance will be achieved within these operating temperatures. If the air conditioner is
used outside the above conditions, the protective device may trip and stop operation of the appliance.
• The temperature of some products is allowed beyond this range for specific situations. Please consult
the merchant. When relative humidity is above 80%, and the air conditioner is running in COOL or DRY
mode with the door of window open for a long period of time, dew may drip down from the outlet.