8

Required Tools/Hardware

• Pencil

• Level

• Tape measure

• Socket wrenches

• Phillips screwdriver

• Adjustable wrench or pliers

• Large flat blade screwdriver

Hardware 

(Included - Packed with the unit)

Tools Required (Not Included) 

 

7/16 inch Locking

screw and Flat 

washer for window

panels

3/4 (or 1/2) inch 

Long Hex-head 

Screw

Safety Lock

1/2 inch Long

screw and Locknut 

3/4 inch Long

Flat Head Bolt 

and Locknut

Sill Angle 

Bracket

Long hex-head

locking screw 

for top angle, 

side retainer 

5 /16 inch Long

2 ea.

4

1

4 ea.

2 ea.

2

10

Foam insert

2

Window sash 

seal foam 

1

INSTALLATION INSTRUCTIONS

Read these instructions completely

and carefully.

IMPORTANT

- Save these instructions.

IMPORTANT

- Observe all

governing codes and ordinances.

Note to Consumer-

 Keep these

instructions for future reference.

Note to Installer-

 Be sure to leave these

instructions with the Consumer.

Completion time- Approximately 1 hour.

Skill level- Installation of this appliance

requires basic mechanical skills.

We recommend that two people install

this product.
Proper installation is the responsibility

of the installer.
Product failure due to improper installation

is not covered under the Warranty.
You MUST use all supplied parts and use

proper installation procedures as described

in these instructions when installing this air

conditioner.

    BEFORE YOU BEGIN

Do not, under any circumstances, cut or

remove the third (ground) prong from the

power cord.

CAUTION

Do not change the plug on the power cord

of the air conditioner.
Aluminum house wiring may present special

problems- consult a qualified electrician.

When handling unit, be careful to avoid cuts from

sharp metal edges and aluminum fins on front and

rear coils.

Summary of Contents for 3PACH18000

Page 1: ...for future reference along with your receipt Your Source for Home Comfort WINDOW AIR CONDITIONER USER MANUAL 17 700 18 500 25 000 28 000 BTU FOR MODELS 3PAHP18002 with 11 200 BTU heat pump 3PACH18000...

Page 2: ...The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air conditioner Disabled persons may req...

Page 3: ...se explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may caus...

Page 4: ...from unit contains contaminants and could cause illness Always insert the filters securely Clean filter AT LEAST once every two weeks NEVER drink water drained from air conditioner Unit and Circuit b...

Page 5: ...breaker have a qualified electrician install the proper receptacle Ensure the receptacle is accessible after the unit installation Do not run air conditioner without side protective cover in place Thi...

Page 6: ...e similar AIR CONDITIONER FEATURES Before you begin thoroughly familiarize yourself with the control panel as shown below and all its functions Then follow the symbol for the functions you desire The...

Page 7: ...mode When in the Cool mode the unit display indicates the set temperature This feature can ONLY be activated from the remote control The remote control serves as a remote thermostat allowing for prec...

Page 8: ...delayed start if the unit is turned off and on quickly After unit is turned off leave unit off for a minimum of 3 minutes before attempting to turn back on This prevents overheating of the compressor...

Page 9: ...p these instructions for future reference Note to Installer Be sure to leave these instructions with the Consumer Completion time Approximately 1 hour Skill level Installation of this appliance requir...

Page 10: ...drapes or blinds will not stop proper airflow 5 Check the available electrical service Power supply MUST be the same as that shown on the unit serial nameplate Power cord is 48 inches long Be sure you...

Page 11: ...ts to holes in top of cabinet where shipping screws were removed from See Fig 6 0 Your unit may come with internal packaging This packaging MUST be removed prior to installing the air conditioner back...

Page 12: ...k center of window sill See Fig 10 2 Place cabinet in window with bottom sill angle firmly seated over window sill as shown See Fig 10A Bring window down temporarily behind top angle to hold cabinet i...

Page 13: ...refully slide into cabinet leaving 6 inches protruding 2 DO NOT push on controls or finned coils 3 Be sure chassis is firmly seated towards rear of cabinet 4 Installation of front is the reverse of re...

Page 14: ...frame construction at ends of windows under truss bearing points etc can be installed stud nearest the center of area where air conditioner thickness of framing material used thickness of framing mate...

Page 15: ...ction refer to Step 2 of Thru The Wall Installation for wall thickness greater than 8 1 2 2 Secure cabinet in place using masonry nails or the right masonry anchor screws Another way to do this is to...

Page 16: ...the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mild liquid dishwashing deterge...

Page 17: ...re and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NO...

Page 18: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in China 877 365 6274 www pe...

Reviews: