background image

10

1  

Remove Chassis

1. Pull down front grille and remove

filter.(See Fig. 1.)

2. Lift front grille upwards and place to one side.

3. Locate and remove the four front screws.

These screws will be needed to re-install

the front panel later. (See Fig. 2.)

4. Push metal cabinet side to release plastic

tabs on each side of front panel.

(See Fig. 3.)

5. Gently lift front panel off unit. (See Fig. 3A.)

6.

 

 

7. Remove shipping screws from top of unit and

also on the side by the base if installed.

(See Fig. 5.)

8. Hold the cabinet while pulling on the base

handle, and carefully remove the unit.

9. Add two foam inserts to holes in top of cabinet

where shipping screws were removed from.

(See Fig. 6.)

0. Your unit may come with internal packaging.

This packaging MUST be removed prior to

installing the air conditioner back into the

cabinet. (See Fig.

• 

Do not lift, pull or remove any expanded 

polystyrene (foam) from inside of the 

air conditioner. It is NOT packing material.

 7.)

2

  Install Top Angle and Side Bracket 

Front Grille

Fig. 1

Fig. 2

Front Panel

Fig. 3

Fig. 3A

Fig. 4

Shipping
Screws

Fig. 5

Fig. 7

Shipping Packaging

Plastic tie

1

1.

2. Install top angle and side retainers to cabinet.

(See Fig. 8.)

Fig. 6

hex

 16

-head

˝ lon

g

d

5/

Fig. 8

Attach foam gasket to top angle above holes.

(See Fig. 6.)

Window Mounting

Disconnect the connector plug of the display

panel from the unit and place front panel to 

one side. (See Fig. 4.)

Summary of Contents for 3PACH18000

Page 1: ...for future reference along with your receipt Your Source for Home Comfort WINDOW AIR CONDITIONER USER MANUAL 17 700 18 500 25 000 28 000 BTU FOR MODELS 3PAHP18002 with 11 200 BTU heat pump 3PACH18000...

Page 2: ...The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air conditioner Disabled persons may req...

Page 3: ...se explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may caus...

Page 4: ...from unit contains contaminants and could cause illness Always insert the filters securely Clean filter AT LEAST once every two weeks NEVER drink water drained from air conditioner Unit and Circuit b...

Page 5: ...breaker have a qualified electrician install the proper receptacle Ensure the receptacle is accessible after the unit installation Do not run air conditioner without side protective cover in place Thi...

Page 6: ...e similar AIR CONDITIONER FEATURES Before you begin thoroughly familiarize yourself with the control panel as shown below and all its functions Then follow the symbol for the functions you desire The...

Page 7: ...mode When in the Cool mode the unit display indicates the set temperature This feature can ONLY be activated from the remote control The remote control serves as a remote thermostat allowing for prec...

Page 8: ...delayed start if the unit is turned off and on quickly After unit is turned off leave unit off for a minimum of 3 minutes before attempting to turn back on This prevents overheating of the compressor...

Page 9: ...p these instructions for future reference Note to Installer Be sure to leave these instructions with the Consumer Completion time Approximately 1 hour Skill level Installation of this appliance requir...

Page 10: ...drapes or blinds will not stop proper airflow 5 Check the available electrical service Power supply MUST be the same as that shown on the unit serial nameplate Power cord is 48 inches long Be sure you...

Page 11: ...ts to holes in top of cabinet where shipping screws were removed from See Fig 6 0 Your unit may come with internal packaging This packaging MUST be removed prior to installing the air conditioner back...

Page 12: ...k center of window sill See Fig 10 2 Place cabinet in window with bottom sill angle firmly seated over window sill as shown See Fig 10A Bring window down temporarily behind top angle to hold cabinet i...

Page 13: ...refully slide into cabinet leaving 6 inches protruding 2 DO NOT push on controls or finned coils 3 Be sure chassis is firmly seated towards rear of cabinet 4 Installation of front is the reverse of re...

Page 14: ...frame construction at ends of windows under truss bearing points etc can be installed stud nearest the center of area where air conditioner thickness of framing material used thickness of framing mate...

Page 15: ...ction refer to Step 2 of Thru The Wall Installation for wall thickness greater than 8 1 2 2 Secure cabinet in place using masonry nails or the right masonry anchor screws Another way to do this is to...

Page 16: ...the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mild liquid dishwashing deterge...

Page 17: ...re and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NO...

Page 18: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in China 877 365 6274 www pe...

Reviews: