To prevent injury to the user or other people and property damage, the following instructions
must be followed. Incorrect operation due to ignoring of instructions may cause harm or
damage. The seriousness is classified by the following indications.

SAFETY PRECAUTIONS

This symbol indicates the possibility of death or serious injury.

Meanings of symbols used in this manual are as shown below.

!

Always do this.

Never do this.

CAUTION

This symbol indicates the possibility of injury or damage to property.

Plug in power plug properly.

Do not modify power cord 
length or share the outlet with 
other appliances.

Always ensure effective 
grounding.

Always unplug the unit if 
strange sounds, smell or 
smoke comes from the unit.

Do not use firearms near unit.

Ventilate room before operating air conditioner  
if there is a gas leak from another appliance 
such as a stove.

Failure to do so may cause 

electric shock or fire due to 

excess heat generation

.

Doing so may cause electric 

shock or fire due to heat 

generation.

Incorrect grounding may cause 

electric shock.

Failure to do so may cause fire 

and electric shock.

Doing so may cause fire.

Failure to do so may cause explosion, 

fire and burns.

Doing so may cause electric 

shock or fire due to heat generation. 

Doing so may cause electric shock.

Doing so may cause failure of

machine or electric shock.

Doing so may cause fire and 

electric shock.

Doing so may cause fire and 

electric shock.

Doing so may cause electric shock

or fire. If the power cord is 

damaged, it must be replaced by the

manufacturer or an authorized 

service center or a similarly qualified 

person in order to avoid a hazard.

This could cause health issues.

Incorrect installation may cause fire 

and electric shock.

Doing so may cause electric shock.

Doing so may cause an explosion or fire.

Doing so may cause failure and 

electric shock.

Do not operate or stop the unit

by inserting or pulling out the 

power plug directly from the wall.

Do not operate with wet hands 
or in damp environment.

Do not allow water to run into 
electric parts.

Do not use the socket if it is 
loose or damaged.

Do not use the power cord close
to heating appliances.

Do not use a damaged power 

Do not direct airflow directly at 
room occupants.

Always install circuit breaker 
and a dedicated power circuit.

Do not open the unit during 
operation.

Do not disassemble, modify, 
or drill holes into the air 
conditioner.

!

!

!

!

!

WARNING

! !

!

! !

!

cord.

Do not use the power cord near flammable gas 
or combustibles, such as gasoline, benzene, 
thinner, etc.

!

!

!

!

!

WARNING

2

Summary of Contents for 3PAC10000

Page 1: ...your window air conditioner please read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort FOR MODELS 3PAC6000 3PAC8000 3PAC10000 3PAC12000 3P...

Page 2: ...it Contact an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that...

Page 3: ...explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may cause...

Page 4: ...main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified serviced technic...

Page 5: ...re hazard or electric shock DO NOT use an extension cord or an adaptor plug DO NOT remove any prong from the power cord WARNING NOTE The power supply cord with this air conditioner contains a current...

Page 6: ...refrigerant passing through evaporator during normal operation High Pitched Chatter High efficiency compressors may have a high pitched chatter during the cooling cycle Vibration Unit may vibrate and...

Page 7: ...esired temperature is seen on the display This temperature will be automatically maintained anywhere between 62 F 17 C and 86 F 30 C If you want the display to read the actual room temperature see To...

Page 8: ...ion or to exhaust stale air Remember to open the vent during this function but keep it closed during cooling for maximum cooling efficiency You can choose any fan speed you prefer During this function...

Page 9: ...uto Start Stop function This feature is a reminder to clean the Air Filter for more ef cient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filter pre...

Page 10: ...is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Up and Down Temp Timer buttons at the same time for 3 seconds The Coo...

Page 11: ...conditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum h...

Page 12: ...r a bench or a table Hold the accordion panel in one hand and gently pull back the center to fill the open end See Fig 1 Fig 1 Lower sash must open sufficiently to allow a clear vertical opening H of...

Page 13: ...ly close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back approximately H Fig 5 above tilted about 3O to 4O downward to the the outside If after proper i...

Page 14: ...slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from between w...

Page 15: ...o unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mild liquid dishwashing...

Page 16: ...and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NOT T...

Page 17: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in China 877 365 6274 www pe...