Read these instructions completely

and carefully.

IMPORTANT

- Save these instructions.

IMPORTANT

- Observe all

governing codes and ordinances.

Note to Consumer-

 Keep these

instructions for future reference.

Note to Installer-

 Be sure to leave these

instructions with the Consumer.

Completion time- Approximately 1 hour.

Skill level- Installation of this appliance

requires basic mechanical skills.

We recommend that two people install

this product.
Proper installation is the responsibility

of the installer.
Product failure due to improper installation

is not covered under the Warranty.
You MUST use all supplied parts and use

proper installation procedures as described

in these instructions when installing this air

conditioner.

    BEFORE YOU BEGIN

Do not, under any circumstances, cut or

remove the third (ground) prong from the

power cord.

CAUTION

Do not change the plug on the power cord

of the air conditioner.
Aluminum house wiring may present special

problems- consult a qualified electrician.

When handling unit, be careful to avoid cuts from

sharp metal edges and aluminum fins on front and

rear coils.

TOOLS YOU WILL NEED

Phillips

Screwdriver

Level

TOOLS YOU MAY USE

Screwdriver

Pencil

Ruler or tape measure

Scissors or knife

NOTE: Save carton and these Installation Instructions for future reference.  

            The carton is the best way to store unit during winter or when not in use.

WINDOW REQUIREMENTS

Your air conditioner is designed to install in 

standard double hung windows with opening 

widths of 23 to 36 inches (584 mm to 914 mm).

NOTE:

 H = vertical opening. See Table 1 on next page. 

INNER

Wooden Windows

OFFSET

H

INTERIOR

WALL

EXTERIOR

WALL

INNER

WINDOW

SILL

Summary of Contents for 3PAC10000

Page 1: ...your window air conditioner please read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort FOR MODELS 3PAC6000 3PAC8000 3PAC10000 3PAC12000 3P...

Page 2: ...it Contact an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that...

Page 3: ...explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may cause...

Page 4: ...main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified serviced technic...

Page 5: ...re hazard or electric shock DO NOT use an extension cord or an adaptor plug DO NOT remove any prong from the power cord WARNING NOTE The power supply cord with this air conditioner contains a current...

Page 6: ...refrigerant passing through evaporator during normal operation High Pitched Chatter High efficiency compressors may have a high pitched chatter during the cooling cycle Vibration Unit may vibrate and...

Page 7: ...esired temperature is seen on the display This temperature will be automatically maintained anywhere between 62 F 17 C and 86 F 30 C If you want the display to read the actual room temperature see To...

Page 8: ...ion or to exhaust stale air Remember to open the vent during this function but keep it closed during cooling for maximum cooling efficiency You can choose any fan speed you prefer During this function...

Page 9: ...uto Start Stop function This feature is a reminder to clean the Air Filter for more ef cient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filter pre...

Page 10: ...is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Up and Down Temp Timer buttons at the same time for 3 seconds The Coo...

Page 11: ...conditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum h...

Page 12: ...r a bench or a table Hold the accordion panel in one hand and gently pull back the center to fill the open end See Fig 1 Fig 1 Lower sash must open sufficiently to allow a clear vertical opening H of...

Page 13: ...ly close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back approximately H Fig 5 above tilted about 3O to 4O downward to the the outside If after proper i...

Page 14: ...slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from between w...

Page 15: ...o unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mild liquid dishwashing...

Page 16: ...and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NOT T...

Page 17: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in China 877 365 6274 www pe...