background image

8

Low

Auto

Med

High

TEMP/TIMER

Auto

Dry

Fan 

Mode

On

Off

Sleep

Timer

Check

Filter

Energy

  Saver

Follow 

   Me

Ion

TIMER: AUTO START/

STOP FEATURE:

Press “Timer”

button

DO THIS:

CHECK FILTER FEATURE:

Press “Check

Filter” button

DO THIS:

FOLLOW ME FEATURE:

CLEAN AIR FEATURE:

(on some models)

Light flashing

Press “Clean

Air” button

DO THIS:

NOTE: TIMER button

First press the “Timer” button. The indicator light

beside the word “On” will illuminate indicating the Auto

Start program is on.

Press or hold the Up or Down Temp/Timer arrows to

 

change the

 

Auto time by 0.5 hour increments, up to 10 hours,

then at 1 hour increments up to 24 hours. 

The control will count down the time remaining until start.

 

The selected time will register for 5 seconds and the

system will automatically revert back to display the previous 

temperature setting.

When the “Timer On” is displayed, press the “Timer” button 

again and the “Timer Off” indicator light illuminates. It indicates 

the Auto Stop program is initiated.

Turning the unit on or off at any time or adjusting the timer setting

to 0.0 will cancel the Auto Start/Stop function.

This feature is a reminder to clean the Air Filter for

more efficient operation. The LED (light) will illuminate after 

250 hours of operation. To reset after cleaning the filter, press

 

the “Check Filter” button and the light will go off.

NOTE: CHECK FILTER button

NOTE: FOLLOW ME indicator light

NOTE: CLEAN AIR button 

To activate the Follow Me feature, point the remote control 

towards the unit and press the “Follow Me” button. The remote 

displays the actual temperature at its location. The remote control 

will send this signal to the air conditioner every 3 minutes  

until the “Follow Me” button is pressed again.  If the unit does

not receive the “Follow Me” signal during any 7 minute interval,  

the unit will beep to indicate the Follow Me mode has ended. 

The actual temperature can be displayed at the unit by 

pressing the “Fan” only mode.  When in the “Cool” mode, the 

unit display indicates the set temperature.

Press the “Clean Air” button.The ion generator is

energized and will help to remove pollen and impurities

from the air and trap them in the filter.

This feature can ONLY be activated from the remote control. 
The remote control serves as a remote thermostat allowing for 
precise temperature control at its location.

AIR CONDITIONER FEATURES (CONTINUED)

Auto

TEMP/TIMER

Auto

On

Off

Sleep

Timer

Check

Filter

Auto

TEMP/TIMER

Auto

On

Off

Sleep

Timer

Check

Filter

Low

Auto

Med

High

Auto

Cool

Dry

Fan 

Fan 

Mode

Sleep

Check

Filter

Ion

Summary of Contents for 2PAC10000

Page 1: ...your window air conditioner please read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort FOR MODELS 2PAC6000 2PAC8000 2PAC10000 2PAC12000 2P...

Page 2: ...t an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do n...

Page 3: ...e explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may cause...

Page 4: ...main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified serviced technic...

Page 5: ...ectric shock DO NOT use an extension cord or an adaptor plug DO NOT remove any prong from the power cord WARNING NOTE The power supply cord with this air conditioner contains a current detection devic...

Page 6: ...ing through evaporator during normal operation High Pitched Chatter High efficiency compressors may have a high pitched chatter during the cooling cycle Vibration Unit may vibrate and make noise becau...

Page 7: ...TO ADJUST FAN SPEEDS Press Fan to select fan speed DO THIS NOTE FAN button There are four 4 fan speeds Auto Low Med or High Each time the button is pressed the fan speed mode is shifted On Dry mode th...

Page 8: ...ion or to exhaust stale air Remember to open the vent during this function but keep it closed during cooling for maximum cooling efficiency You can choose any fan speed you prefer During this function...

Page 9: ...ient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off NOTE CHECK FILTER button NOTE FOLLO...

Page 10: ...Celsius To convert from one to the other press and hold the Up and Down Temp Timer buttons at the same time for 3 seconds The Cool circuit has an automatic 3 minute time delayed start if the unit is...

Page 11: ...conditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum h...

Page 12: ...r a bench or a table Hold the accordion panel in one hand and gently pull back the center to fill the open end See Fig 1 Fig 1 Lower sash must open sufficiently to allow a clear vertical opening H of...

Page 13: ...ly close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back approximately H Fig 5 above tilted about 3O to 4O downward to the the outside If after proper i...

Page 14: ...slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from between w...

Page 15: ...e air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent...

Page 16: ...and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NOT T...

Page 17: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in PRC 877 365 6274 www per...

Reviews: