background image

7

Low

Fan 

Mode

Energy

  Saver

Follow 

   Me

Ion

TO SELECT THE 

OPERATING MODE:

Press the  

“Mode” button.

DO THIS:

TO USE THE ENERGY

SAVER FEATURE:

Press the 

“Energy Saver”

button

DO THIS:

SLEEP FEATURE:

Press “Sleep”

button

DO THIS:

In this mode the selected temperature will increase by 

2

O

F/1(or 2)

O

C 30 minutes after the mode is selected. The 

temperature will then increase by another 2

O

F/1(or 2)

O

after an additional 30 minutes. This new temperature 

will be maintained for 6 hours before it returns to the 

originally selected temperature. This ends the Sleep  

mode and the unit will continue to operate as originally 

programmed. The Sleep mode program can be  

cancelled at any time during operation by again 

pressing the “Sleep” button.

NOTE: SLEEP button

To choose operating mode, press the “Mode” button. 

Each time you press the button, a mode is selected 

in a sequence that goes from “Auto,” “Cool,” “Dry,”

and “Fan.” The indicator light will be illuminated and

remain on once the mode is selected. 

The unit will 

automatically initiate the Energy Saver function 

under “Cool,” “Dry,” and “Auto” (only Auto-Cooling 

and Auto-Fan) modes.

NOTE: MODE button

To operate on “Auto” feature:

 

To operate on “Fan” only (not available on all models):

Use this function only when cooling is not desired, 

such as for room air circulation or to exhaust stale

air. (Remember to open the vent during this function, 

but keep it closed during cooling for maximum cooling 

efficiency.) You can choose any fan speed you prefer.

During this function, the display will show the actual

room temperature, not the set temperature as in the

cooling mode.

NOTE: ENERGY SAVER button

To operate on “Dry” mode:

In this mode, the air conditioner will reduce air humidity.

If the space is a closed or sealed area, some degree of 

cooling will continue.

When you set the air conditioner in “Auto” mode, it will 

automatically select cooling, heating (on models with heating

capabilities), or fan only operation depending on what 

temperature you have selected and the room temperature.

The air conditioner will control room temperature 

automatically around the temperature you set.

In this mode, the fan speed cannot be adjusted.

 

It starts automatically at a speed according to the 

room temperature. If the room does not get too warm,

it will stay at “Low” speed.

This function is available on “Cool,” “Dry,” and “Auto” 

(only Auto-Cooling  and Auto-Fan) modes. In this 

mode,the fan will continue to run for 3 minutes after the 

compressor shuts off.The fan then cycles on for 2 

minutes,at 10 minute intervals, until the room 

temperature is above the set temperature, at which 

time the compressor turns back on and cooling starts.

AIR CONDITIONER FEATURES (CONTINUED)

Low

Auto

Med

High

Auto

Cool

Dry

Fan 

Fan 

Mode

Ion

Auto

TEMP/TIMER

Auto

On

Off

Sleep

Timer

Check

Filter

Summary of Contents for 2PAC10000

Page 1: ...your window air conditioner please read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort FOR MODELS 2PAC6000 2PAC8000 2PAC10000 2PAC12000 2P...

Page 2: ...t an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do n...

Page 3: ...e explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may cause...

Page 4: ...main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified serviced technic...

Page 5: ...ectric shock DO NOT use an extension cord or an adaptor plug DO NOT remove any prong from the power cord WARNING NOTE The power supply cord with this air conditioner contains a current detection devic...

Page 6: ...ing through evaporator during normal operation High Pitched Chatter High efficiency compressors may have a high pitched chatter during the cooling cycle Vibration Unit may vibrate and make noise becau...

Page 7: ...TO ADJUST FAN SPEEDS Press Fan to select fan speed DO THIS NOTE FAN button There are four 4 fan speeds Auto Low Med or High Each time the button is pressed the fan speed mode is shifted On Dry mode th...

Page 8: ...ion or to exhaust stale air Remember to open the vent during this function but keep it closed during cooling for maximum cooling efficiency You can choose any fan speed you prefer During this function...

Page 9: ...ient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off NOTE CHECK FILTER button NOTE FOLLO...

Page 10: ...Celsius To convert from one to the other press and hold the Up and Down Temp Timer buttons at the same time for 3 seconds The Cool circuit has an automatic 3 minute time delayed start if the unit is...

Page 11: ...conditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum h...

Page 12: ...r a bench or a table Hold the accordion panel in one hand and gently pull back the center to fill the open end See Fig 1 Fig 1 Lower sash must open sufficiently to allow a clear vertical opening H of...

Page 13: ...ly close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back approximately H Fig 5 above tilted about 3O to 4O downward to the the outside If after proper i...

Page 14: ...slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from between w...

Page 15: ...e air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent...

Page 16: ...and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NOT T...

Page 17: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in PRC 877 365 6274 www per...