3

IMPORTANT SAFETY INSTRUCTIONS

 NOTE:

The power supply cord with this air 

conditioner contains a current detection 

device designed to reduce the risk 

of fire. Please refer to the section 

“Operation of Current Device” (below) 

for details. In the event that the power 

supply cord is damaged, it cannot be 

repaired. It must be replaced by an 

authorized repair technician with a cord 

from the Product Manufacturer.

WARNING

Avoid fire hazards or electric shock. 

DO 

NOT 

use an extension cord or an adapter 

plug. 

DO NOT

 remove any prong from the 

power cord.

OPERATION OF  

CURRENT DEVICE:

The power supply cord contains a 

current device that senses damage 

to the power cord. To test your power 

supply cord, do the following: 

1.  Plug in the air conditioner.

2.  The power supply cord will have 

TWO buttons on the plug head. Press 

the TEST button. You will notice a 

click as the RESET button pops out.

3.  Press the RESET button. Again,  

you will notice a click as the  

button engages.

4.  The power supply cord is now 

supplying electricity to the unit. (On 

some products this is also indicated 

by a light on the plug head.)

WARNING

FOR YOUR SAFETY: Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other appliances.

WARNING - PREVENT ACCIDENTS

To reduce the risk of fire, electrical shock, or injury to persons when using 

your air conditioner, follow basic precautions, including the following: 

●  Be sure the electrical service is adequate for the model you have 

chosen. This information can be found on the serial plate, which is 

located on the side of the cabinet and behind the grille.

●  If the air conditioner is to be installed in a window, you will probably 

want to clean both sides of the glass first. If the window is a triple-

track type with a screen panel included, remove the screen completely 

before installation.

●  Be sure the air conditioner has been securely and correctly installed 

according to the installation instructions in this manual.

●  Save this manual for possible future use in removing or installing this unit.

●  When handling the air conditioner, be careful to avoid cuts from sharp 

metal fins on front and rear coils.

WARNING - ELECTRICAL INFORMATION

The complete electrical rating of your new room air conditioner is  

stated on the serial plate. Refer to the rating when checking the  

electrical requirements.

●  Be sure the air conditioner is properly grounded. To minimize shock 

and fire hazards, proper grounding is important. The power cord is 

equipped with a three-prong grounding plug for protection against 

shock hazards. 

●  Your air conditioner must be used in a properly grounded wall 

receptacle. If the wall receptacle you intend to use is not adequately 

grounded or protected by a time delay fuse or circuit breaker, have a 

qualified electrician install the proper receptacle.

●  Ensure the receptacle is accessible after the unit installation.

●  Do not run air conditioner without side protective cover in place. This 

could result in mechanical damage within the air conditioner.

●  Do not use an extension cord or an adapter plug.

 NOTE:

Do not use the plug to turn the unit on or off.

●  Always make sure the RESET button is pushed in for correct operation.

●  The power supply must be replaced if it fails reset when either the TEST 

button is pushed or it cannot be reset.

●  If power supply cord is damaged, it cannot be repaired. Please call 

Consumer Services at 844-472-2473 to assist with replacement.

NOTE:

 This air conditioner is designed to be operated under the

following conditions:

Cooling 

Operation

Outdoor Temp:

69 – 109°F/21 – 43°C

Indoor Temp:

61 – 90°F/16 – 32°C

Performance may be reduced outside of these operating temperatures.

Grounding Type

Wall Receptacle

Do not, under any 

circumstances, cut, 

remove, or bypass the 

ground prong.

Power supply cord  

with 3-prong grounding 

plug and current 

detection device

Summary of Contents for 1PEC10000

Page 1: ...WINDOW AIR CONDITIONER FOR MODELS 1PEC8000 1PEC10000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...an installer for installation of this unit The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with th...

Page 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Page 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Page 6: ...before installation Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing...

Page 7: ...LEFT RIGHT LOUVER ADJUSTMENT Carefully push the air direction control tab left or right to adjust the horizontal air direction 6 CONTROL PANEL 7 POWER CORD 8 FRONT GRILLE Air filter is located behind...

Page 8: ...or 12000 BTU units Side louvers and the rear of the air conditioner must have clear air space to allow enough airflow through the condenser for heat removal The rear of the unit must be outdoors not i...

Page 9: ...t the accordion panels into the top and bottom rails of the air conditioner Fasten the accordion panels to the unit with 4 small screws A 3 8 in as shown in figure below Place top screw first but do n...

Page 10: ...ttom of the accordion panel with Type B Wood Screws as shown Repeat this step on the opposite side 3 Install Curtain Locks F to the bottom middle of the accordion panel frame one on each side Secure C...

Page 11: ...room In DRY mode the temperature 77 F and fan speed Low are present and cannot be adjusted Press the MODE button until DRY indicator is on FAN Mode Use this mode to circulate the air in the room with...

Page 12: ...l panel reminding you to clean the filter Press this button to turn off the CHECK FILTER LED light on the unit and reset the check filter timer for 250 hours 11 TIMER Button Press this button to set t...

Page 13: ...re or damage to parts 4 Clean the air conditioner Use a soft dry cloth to wipe the air conditioner or use a vacuum cleaner to do the cleaning If the air conditioner is very dirty you may use a cloth s...

Page 14: ...hten tube away from coil Make sure nothing is blocking the grille or side vents Make sure there is no dirt or debris inside the unit or on the filter UNIT WILL NOT TURN ON Reset circuit breaker Make s...

Page 15: ...REVIEW THE CHART BELOW ISSUE POSSIBLE CAUSES FOG IS BLOWN OUT DURING THE COOLING OPERATION When the indoor temperature and humidity is high this may occur When the indoor temperature and humidity dro...

Page 16: ...ect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_1PEC8000_...

Reviews: