Perel GMK2 User Manual Download Page 4

GMK2_v2 

PEREL 

4

 

3. Use 

 

 

Place the mosquito trap on a flat and stable surface. For best results, install the mosquito trap approximately 

1.5m above the ground. 

 

Connect the mosquito trap to the mains. 

 

Switch the mosquito trap on or off with the on/off switch. 

 

Empty the mosquito trap. 

 

4. Emptying and Cleaning the Mosquito Trap 

 

 

Turn the base in an anticlockwise direction. Clean out the base using the 
included brush. 

 

 

 

Separate the fan from the upper part using an appropriate Phillips-head 

screwdriver. 

 

Clean the fan using the included brush or a slightly damp cloth. 

 

 

 

Clean the UV lamp using the included brush. 

 

5. Replacing  the  UV-lamp 

 
Refer to the pictures on page 2 of this manual. 

 

Switch off the lamp and disconnect the mains. 

 

Remove the collecting container (1). To do this, twist the container counter clockwise and pull (see picture A). 

 

Remove the 4 screws that keep the lamp holder section (2) and fan section (3) together (see picture B). 

 

Pull the lamp holder section (2) and fan section (3) apart. Be careful not to damage the electrical leads. The 
cone (4) can also be removed if necessary (see picture C). 

 

To remove the UV-lamp, gently turn it a quarter and pull it out of the sockets. 

 

Place the new UV lamp in the sockets and turn a quarter to secure it. 

 

Re-position the cone (4), guiding the electricity leads through the gap. 

 

Put the lamp holder section (2) on top of the fan section (3) with the screw holes lined up, making sure the 

electrical leads don’t get damaged. Push until a click is heard and remount the 4 screws. 

 

Re-install the collecting container (1). Place it on the fan section (3) and turn clockwise until it is secured. 

 

6. Technical  Specifications 

 
Power Supply 

220 ~ 240VAC/50Hz 

Power Consumption 

26W 

Dimensions 

250 x 250 x 320mm 

Total Weight 

1.7kg 

 
Velleman nv cannot be held responsible in the event of damage or injury resulted from (incorrect) use of 
this device. 
 
For more info concerning this product, please visit our website www.perel.eu. 
The information in this manual is subject to change without prior notice. 
 

Summary of Contents for GMK2

Page 1: ...26W MUGGENVAL VIA FOTOKATALYSE 26W TRAMPA PARA MOSQUITOS POR FOTOCAT LISIS 26W M CKENVERTREIBER BER PHOTOKATALYSE 26W ARMADILHA PARA MOSQUITOS FOTOCATAL TICA 26W USER MANUAL NOTICE D EMPLOI GEBRUIKERS...

Page 2: ...r C panneau photocatalytique D ouverture E filet A UV lamp B ventilator C fotokatalytisch paneel D vangopening E net A bombilla UV B ventilador C panel fotocatal tico D agujero E red A UV Lampe B L ft...

Page 3: ...the trap Titanium dioxide TiO2 Photocatalysis is a catalytic reaction formed when TiO2 is irradiated by near ultraviolet rays from the sun or a light source In the presence of near ultraviolet light...

Page 4: ...3 together see picture B Pull the lamp holder section 2 and fan section 3 apart Be careful not to damage the electrical leads The cone 4 can also be removed if necessary see picture C To remove the U...

Page 5: ...in Le dioxyde de titane TiO2 La photocatalytique est une r action catalytique r sultant d une r action chimique lorsque le dioxyde de titane TiO2 est irradi par des rayons UVA et UVB provenant du sole...

Page 6: ...Desserrer les quatre vis de fixation de la partie sup rieure 2 et du ventilateur 3 voir ill B S parer la partie sup rieure 2 et le ventilateur 3 en veillant ne pas endommager le c blage Retirer le c n...

Page 7: ...ze reactie bootst het menselijke lichaam na en zorgt ervoor dat de muggen in de val worden gelokt Titaniumdioxide TiO2 Fotokatalyse is een katalytische reactie waarbij TiO2 bestraald wordt door UVA en...

Page 8: ...klok in en trek zie figuur A Verwijder de vier schroeven van de lamphouder 2 en de ventilator 3 zie figuur B Verwijder de lamphouder 2 van de ventilator 3 zonder de bekabeling te beschadigen Verwijder...

Page 9: ...humano El di xido de titanio TiO2 La fotocat lisis es una reacci n catal tica causada por una reacci n qu mica si el di xido de titanio TiO2 est irradiado por rayos UVA y UVB que vienen del sol u otra...

Page 10: ...fijaci n de la parte superior 2 y del ventilador 3 v ase fig B Aseg rese de que no da e el cableado al separar la parte superior 2 y el ventilador 3 Quite la parte central 4 si fuera necesario v ase f...

Page 11: ...schen UVA und UVB Strahlen und eine Schicht aus Titandioxid TiO2 Diese Reaktion ahmt den menschlichen K rper nach und sorgt daf r dass die M cken in die Falle gelockt werden Titandioxid TiO2 Photokata...

Page 12: ...e die vier Schrauben des Lampenhalters 2 und des L fters 3 siehe Abb B Entfernen Sie den Lampenhalter 2 vom L fter 3 ohne die Verdrahtung zu besch digen Entfernen Sie das Mittelst ck 4 wenn n tig sieh...

Page 13: ...ios UVA e UVB e p di xido de tit nio TiO2 imitando o corpo humano Di xido de tit nio TiO2 O fotocatal tico uma reac o catal tica resultando de uma reac o qu mica quando o di xido de tit nio TiO2 irrad...

Page 14: ...Desapertar os quatro parafusos de fixa o da parte superior 2 e do ventilador 3 ver ill B Separar a parte superior 2 e o ventilador 3 tendo cuidado com as liga es Retirar o cone 4 se necess rio ver il...

Reviews: