E-TX-21-0014 Rev IR  Installation Manual, TXA201 Triaxial Accelerometer 

 

 

1.2  CAUTION 

The TXA201 Triaxial Accelerometer can be damaged by static electricity. Observe ESD 

(electrostatic discharge) procedures when handling the unit.  
Verify  that  power and ground leads are terminated correctly in the mating connector 

before applying power to the unit. Damage to the internal components may occur if power 

is applied incorrectly.  
Cap the electrical connector when the accelerometer is disconnected or not installed.  
Failure to follow these precautions may void the equipment warranty.  
 

1.3  IDENTIFICATION 

  Texas Aerospace Part Number: TA20001-00 

  Peregrine Part Number: PA-210618-801 

  Placard 

An identifying placard is affixed to the accelerometer prior to delivery. The placard 

includes a serial number of the format ”0000” with the serial number of the first unit 

being 1001. 
The placard also serves as an anti-tamper device. The placard is installed over one of 

the assembly screws. Removing or damaging the placard to access the screw will void 

the equipment warranty.  

2  EQUIPMENT DETAILS 

2.1  Mechanical  

  Mounting 

The TXA201 is designed to meet ARINC 542A mounting specifications and attaches with 

four (4) #10 Pan Head Steel Fasteners.  This equipment may be installed  in a 

compartment that is non-pressurized and not temperature-controlled.  

  Alignment 

The unit should be mounted with base of the accelerometer facing down on flat and level 

(within 4 degrees), rigid aircraft structure. Shock mounts or vibration dampeners should 

not be used when mounting this unit. Ensure the alignment notch (R.20 in Figure 3 below) 

is facing forward. Verify alignment using the arrows on the identification placard.  
 

 

Summary of Contents for TXA201

Page 1: ...SION STATUS Rev Description Approved Date IR Initial Release T Bailey 7 7 22 Export Control Notice The technical data contained herein is controlled under the U S Export Administration Regulations EAR...

Page 2: ...N 8 3 1 TSO 8 3 2 Application 8 3 3 Environmental 8 3 4 Installation Approval 9 4 TESTING 9 4 1 Fault Indication 9 4 2 Pre Installation Check 9 4 3 Functional Test Procedure 9 4 4 Post Installation Ch...

Page 3: ...Center of Gravity DC Direct Current DO Document Order EQ Equipment Qualification ESD Electro Static Discharge FAA Federal Aviation Administration FDR Flight Data Recorder FSO Full Scale Offset MDL Mas...

Page 4: ...designed to meet ARINC 542A mounting specifications and is sealed to prevent moisture incursion This accelerometer may be utilized as an input to flight data recorder FDR systems such as the Curtiss...

Page 5: ...to the accelerometer prior to delivery The placard includes a serial number of the format 0000 with the serial number of the first unit being 1001 The placard also serves as an anti tamper device The...

Page 6: ...ial Accelerometer 6 Location The accelerometer should be mounted within 12 feet longitudinally and 6 feet laterally of the aircraft center of gravity to avoid erroneous readings due to aircraft rotati...

Page 7: ...5000mV DOWN 3g 200mV FWD 1g 5000mV AFT 1g 200mV RIGHT 1g 5000mV LEFT 1g 200mV Axial Null VERTICAL 1800 mV LONGITUDINAL 2600 mV LATERAL 2600 mV Excitation 18 TO 32 VDC 28 VDC nominal Supply Current 30...

Page 8: ...tested to Category B Vibration 8 0 Equipment tested to Category S and H aircraft zone 1 for fixed wing aircraft fuselage using vibration test curves C3 and R Explosive Atmosphere 9 0 Equipment identi...

Page 9: ...rformed using the following procedure Requirements 28VDC Power Supply DC Voltmeter Tooling fixtures or other items that will allow the accelerometer to be rested on each of its six faces in a flat and...

Page 10: ...a is properly received and is within expected parameters Table 2 Test Orientations and Outputs Axis Orientation Position Arrow UP Gravity Output and Range Vertical 3 0g Pin C 1 800 0036 VDC 1 1g Pin C...

Page 11: ...and a cotton cloth or swabs A soft bristled brush may also be used 5 3 Repair The TXA201 Accelerometer contains no user serviceable parts and is not designed to be adjusted or repaired by field person...

Reviews: