Percy Doughty & Co FIREFOX 5 CLEAN BURN II Installation And Operating Instructions Manual Download Page 3

Typical Installation Into Infilled Masonary Fireplaces 

 

Soot Door 

Seal with fireproof lagging 

Max150mm 

Infill 

45 deg minimum 

14 

1 FFX008 

Flue 

Collar 

FFX009 

Flue Blanking Plate 

3,5,6 

FFX001 

Stove Body (Rear,Right,Left Panel) 

FFX003 

Stove Top Panel 

FFX002 

Stove Base Panel 

FFX005 

Grate Support Plate 

9 FFX006 

Grate 

10 

FFC007 

Stove Baffle Plate 

11 

FFX012 

Side Brick  

12 FFX013 

Back 

Brick 

13 FFX010 

Leg 

 

14,15 

FFX004 

Stove Door + Front Panel 

16 FFX014 

Ash 

Pan 

17 FFX011 

Fret 

18 FFC024 

Secondary 

Air 

Duct 

19 FFX018 

Door 

Glass 

20 

FFX027 

Glass Panel Seal 

21 FFX026 

Door 

Seal 

22 FFX023 

Secondary 

Air 

Slide 

23,26,30 

FFX022          

Primary, Sec Riddling Knob Set 

25 

FFX020 

Primary Air Slide  

27 FFX029 

Operating 

Tool 

28 FFX1 

Mitten 

29 

FFX015 

Grate Riddling Rod 

31 

FFX016, FFX017      

Door Handle Assembly 

32 

FFX019 

Door Glass Retaining Tabs 

33 FFX028 

Hinge 

Pin 

34 

Stove Identification Label  

Firefox 5 CB II Parts List 

Summary of Contents for FIREFOX 5 CLEAN BURN II

Page 1: ...ercydoughty com web www percydoughty co uk Essential characteristic Test fuel Beech Anthracite Fire Safety Pass Pass Emission of combustion products related to 13 O2 CO 0 11 vol Dust 73 mg m0 3 NOx 98...

Page 2: ...Dimensions may vary slightly the manufacturers reserve the right to adjust them without notice 15 Key To Dimensions A Height B Width C Centreline of Flue D Height To Centre of Rear Flue E Depth F Rea...

Page 3: ...1 FFX012 Side Brick 12 FFX013 Back Brick 13 FFX010 Leg 14 15 FFX004 Stove Door Front Panel 16 FFX014 Ash Pan 17 FFX011 Fret 18 FFC024 Secondary Air Duct 19 FFX018 Door Glass 20 FFX027 Glass Panel Seal...

Page 4: ...nts are not met the chimney should be lined by a suitable method The chimney height and the position of the chimney terminal should conform to Building Regulations A flue draught of minimum 12 Pascals...

Page 5: ...ombustible hearth Allow an apron of at least 300mm at the front of the stove and 150mm on either side The hearth on which the stove is to be placed should not be less than 125mm thick if the floor is...

Page 6: ...he firebed and allow the fire to burn over the entire area of the grate Insert peg on operating tool into hole in riddling rod draw tool forwards and backwards with a slow positive action Set rod in b...

Page 7: ...uel Anthracite large nuts briquette smokeless fuel i e Ancit Phurnacite Taybrite Homefire Ovals suitable for closed appliances Please note that when refuelling with solid fuel do not pile fuel higher...

Page 8: ...el collar replacement or stove pipe must be carried out by a suitably qualified engineer 9 General Maintenance Baffle Plate This should be removed at least once a month to prevent any build up of soot...

Reviews: