ST-01 Speed gate, STD-01 Double-sided section
Connector blocks to connect:
X1 (Power
)
– speed gate power supply.
X2 (RC)
– operating devices: RC-panel, wireless remote control, control outputs of the
ACS-controller, Fire Alarm
device
.
X3 (ACS)
– sirens and ACS-controller inputs to the control board outputs.
X4
– remote indication blocks to the controller board relay outputs.
X5
– DC and CAN connection cables of swing panel motor drives.
X9
–
mini-USB
connector for speed gate built-in software update.
Connectors for jumper installation:
XP1 (Program)
– secondary connector.
XP2 (Mode 1)
– connector not used (jumper installed upon delivery).
XP3 (+12V)
– connector for turning on LED indication on the control board.
XP4 (Update)
– connector for switching the control board to a Software update mode
through USB interface. The jumper is removed by default.
XP6 (BUZZ)
– connector for turning on the buzzer on the control board. Buzzer operation
duplicates operation unit sound indication and siren activation. The jumper is installed by
default, which corresponds to the activated buzzer.
XP7 (Mode2)
– not used. During the operation the jumper should be removed.
Switchers:
Pulse
– to turn the speed gate to a pulse control mode. By default, the switch is in
ON
position, which corresponds to a pulse speed gate operating mode.
FA_Dir
– to choose swing panel direction of rotation in case an emergency passage
opening (
Fire Alarm)
signal is sent. By default, the switch is in
OFF
position, which
corresponds to the swing gate being opened in B direction.
Size1
,
Size2
– to set the speed gate swing panels size. By default, both switches are in
OFF
position.
Table 1. Positioning of
Size1
,
Size2
switches according to the swing panel type
Switcher positioning
Swing panel model
Size1
Size2
ATG-300
ON OFF
ATG-300H
ON ON
ATG-425, ATG-475
OFF OFF
Test1
– not used. When operating, the switch must be in OFF position.
Test2
– for turning on LED indication on intrusion detectors boards. By default, both switches
are in
OFF
position, which corresponds to the indication being switched off.
R1
– turns on the “
Auto-opening
in the selected direction
” mode (Sect. 8.8). By default, the
switch is turned
OFF
R2
– switches the speed gate to the training mode (Sect. 8.7), if the
R1
switch is in
OFF
position, or is used for selecting the direction of “
Auto-opening
” mode if the
R1
switch is in
ON
position. By default, the switch is set in
OFF
position (see Table 2).
Table 2. Speed gate operating modes in different positions of R1 and R2 switches
Switch position
R1
R2
Mode
OFF
OFF
Training and “
Auto-opening
” modes are turned on
OFF
ON
Training mode is switched on (Sect. 8.7
)
ON OFF
"
Auto-opening
”
mode is switched on in A direction (Sect. 8.8)
ON ON
“
Auto-opening
”
mode is switched on in B direction (Sect. 8.8)
15