background image

Assembly and Operation Manual 

 

1. APPLICATION  

The 

L

С

-72.4 electromechanical mortise door lock

 (hereinafter – the lock) is designed to 

control light and medium office doors.  
The lock can be installed in wooden and non-metal doors 38–50 mm thick. The lock is universal 
because it is compatible both with right-handed and left-handed doors using standard lock 
cylinders (Chapter 6).   
The lock is designed to work as a part of access control system (ACS).  

2. TECHNICAL SPECIFICATIONS  

Technical parameters of the lock comply with GOST 538-2001 and GOST 5089-2003.  
The lock with regard to unauthorized access protection complies with GOST 

Р

 51241-2008 

(means of normal protection).   
The lock resistance to opening complies with GOST 5089-2003, class 1.  
DC voltage.................................................................................................................... 11 – 13 V 
Operational current................................................................................................. 0.08 – 0.12 A 
Lock cylinder type............................................................................................................ pin-type 
Bolt throw, day-time mode.................................................................................................11 mm 
Bolt throw, night-time mode............................................................................................18.5 mm 
Product type .................................................................................................................... fail-safe 
Dimensions........................................................................................................105×20×150 mm 
Centre-to-centre spacing...................................................................................................72 mm 
MTBF ........................................................................................... 200000 number of operations 
Average lifetime............................................................................................................... 8 years 
Protection class .....................................................................................................III at IEC335-1 
Weight .........................................................................................................not more than 0.5 kg 

3. STANDARD DELIVERY SET  

Electromechanical mortise lock .................................................................................................1 
Strike plate ................................................................................................................................1 
Screw 4×30 ...............................................................................................................................4 
Package box ..............................................................................................................................1 
Assembly and operation manual ...............................................................................................1 
Installation template ..................................................................................................................2 
The lock cylinder with a set of keys, door levers with fixing elements, control cable are not 
included in the delivery set. They should be provided by the Customer.   

4. OPERATION CONDITIONS  

The lock with regard to resistance to environmental exposure complies with GOST 15150-69, 
category NF4 (operation in premises with climate control). Operation of the lock is allowed at 
ambient air temperature from +1°

С

 to +45°

С

 and at relative air humidity of 75% at +15°

С

5. SAFETY REQUIREMENTS 

The lock safety requirements comply with GOST R IEC 335-1-94. The electric shock protection 
class is III as per GOST R IEC 335-1-94, clause 2.4.10. 

Summary of Contents for LC-72.4

Page 1: ...Assembly and operation manual Electromechanical LC 72 4 Lock...

Page 2: ...Electromechanical Lock LC 72 4 Assembly and Operation Manual...

Page 3: ...y time mode 11 mm Bolt throw night time mode 18 5 mm Product type fail safe Dimensions 105 20 150 mm Centre to centre spacing 72 mm MTBF 200000 number of operations Average lifetime 8 years Protection...

Page 4: ...is resistant to self opening for instance as the result of a hard kick on the door the control cable is laid through the door leaf with pliant coupling low power consumption the design of the lock doe...

Page 5: ...r after the locking device is released Until the locking device is released the lever is blocked from turning Unblocking of the lock is performed by turning the key in lock cylinder counter clockwise...

Page 6: ...ay time mode after that 8 INSTALLATION INSTRUCTIONS Making of holes in the door leaf for installing the lock 1 lock cylinder door lever forend and strike plate 8 in the door frame should be made accor...

Page 7: ...ade by sinking the locking bolt The day night mode switch frees the locking bolt and after sinking it moves out for additional 7 5 mm After that the bolt is blocked Opening of the lock in night time m...

Page 8: ...door lock the Product complies with applicable statutory safety requirements electromagnetic compatibility provided that the instructions on storage installation and operation given in the Assembly O...

Page 9: ...PERCo P O Box 87 Saint Petersburg 194295 Russia Tel 7 812 321 61 72 Fax 7 812 516 48 76 e mail support perco ru www percoweb com...

Page 10: ...www perco ru www percoweb com...