2.2.2. Heat pump installation.
①
The frame can be fixed by bolts (M10) on concrete foundation or brackets. The
concrete foundation must be solid; the bracket must be strong enough and anti-rust treated;
②
The appliance needs a water pump (Not supplied). The recommended pump
specification-flux: refer to Technical Parameter, Max. lift ≥10m
③
When the appliance is running, its normal to have condensation water discharged from
bottom, install the drain hose supplied properly to let out condensation water if necessary.
2.2.3. Wiring and protecting devices and cable specification
①
Connect to appropriate power supply, the voltage should comply with the rated voltage
of the products.
②
Earth the appliance well.
③
Wiring must be done by certified electrical technician according to the circuit diagram.
④
Set breaker or fuse according to local code (Rated residual action current ≤ 30mA).
⑤
The layout of power cable and signal cable should be put in order and not affecting
each other.
A
B
C
D
E
F
G
H
75067
315 590 312 340 961 340 74
658
74787
315 590 312 340 961 340 74
658
74788
395 590 392 420 961 390 74
658
75074
395 590 392 420 961 460 74
758
75068
395 720 391 420 1092 620 74
958
75069
505 790 496 530 1161 650 74
958
Name
Size(mm)
Model
C
H
D
A
E
F
G
B