11
OPERATION:
The equipment mainly performs the water filtration function as described in this manual.
For the correct functioning of the filter and the correct management of the system to which it is connected, other
functions are foreseen.
These functions take place through a different setting of the 6-way valve connected to the filter (supplied with the filter).
The valve has 6 positions:
Filtration
Backwash
Rinse
Waste
Circulation
Closed
The operating conditions for each position are detailed below.
ENGLISH
CAUTION:
The selection of the 6-way valve lever must be carried out ONLY AND EXCLUSIVELY TO
THE STATIONARY SYSTEM when the pump is off.
Filtration
It is the normal operating position, performs the function of filtering the pool water between the inlet and the outlet of the
filter.
Observe the pressure gauge regularly, it is recommended to proceed with the backwash operation when the pressure
exceeds 1,1 kg/cm .
Backwash
It is used to clean the filteration media by removing the
retained parts during normal operation. This function must
be combined with the opening of the waste valve with
which it should be equipped.
Recommended operation time: 2-3min
It is recommended to do a backwash every two weeks and immedaitely after a vaccum cleaning of the pool.
Rinse
It is an operation to be carried out after backwashing to remove any impurities left inside the valve after backwashing.
Recommended operating time: 1min
Waste
It is the position of by-passing the inlet water directly to the drain (e.i. pool emptying).
Circulation
It is the position that allows the system to operate without the filter function. The water is bypassed directly to the outlet.
Closed
It is the position that closes all the valve passages.
Winterizing
It is an intermediate position (0) which, with an empty system,
allows to prevent possible freezing failures.
0,8 kg/cm² - 11,4 PSI:
Normal Working Pressure
1,3 kg/cm² - 18,5 PSI:
Proceed with Backwash operation
(0) Winterizing