Installation
2
0
2
2
-0
2
15
3
Installation
3.1
Storage and Disposal
Keep the original packaging. Always store and transport the device in the original packaging.
Store the device in a clean and dry environment. The permitted ambient conditions must be
considered, see datasheet.
The device, built-in components, packaging, and any batteries contained within must be dis-
posed in compliance with the applicable laws and guidelines of the respective country.
3.2
Preparation
Unpacking the Device
1.
Check the packaging and contents for damage.
In the event of damage, inform the shipping company and notify the supplier.
2.
Check the package contents against your order and the shipping documents to ensure that all
items are present and correct.
Should you have any questions, direct them to Fuchs.
3.
Retain the original packaging in case the device is to be stored or shipped again at a later date.
3.3
Mounting the Camera
The surface must be level to prevent the housing from becoming misaligned when the fittings
are tightened. Following installation of the sensor, ensure that there is still sufficient space to
connect the connection cable to the sensor
Mounting the Housing
So that the sensor can easily be mounted in your plant, the device has four M6 threads on the
mounting fixture.
Caution!
Damage to the equipment caused by improper mounting!
Device components can be damaged if the permissible screw-in depth and the maximum per-
missible tightening torque is exceeded.
Note that the threads on the bottom of the housing are not thru–holes.
Observe the maximum permissible screw-in depth to avoid damaging the device or mounting it
incorrectly.
Never exceed the maximum permissible tightening speed for the fixing screws. The maximum
tightening torque of the fixing screws must not exceed 1 Nm.