17
connected devices.
Figure 8.2 RS232 control signals
If the RTS/CTS handshaking protocol is enabled, the VB14 activates the RTS232
output to indicate a message is to be transmitted. The receiving unit activates the
CTS232 input to enable the transmission.
RS485 full-duplex interface
The RS485 full-duplex interface is used for non-polled communication protocols in
point to point connections over longer distances than those acceptable for RS232
communications or in electrically noisy environments.
The connector pinout follows:
Connector
25-pin
Name
Function
2
TX485+
RX485 transmitted data +
4
TX485-
RX485 transmitted data -
3
RX485+
RX485 received data +
5
RX485-
RX485 received data -
7
SGND
Signal ground