![Pepperl+Fuchs VAA-2E2A-KE1-S/E2 Original Operating Instructions Download Page 15](http://html1.mh-extra.com/html/pepperl-fuchs/vaa-2e2a-ke1-s-e2/vaa-2e2a-ke1-s-e2_original-operating-instructions_1527688015.webp)
VAA-2E2A-KE1-S/E2, VAA-2E2A-KE1P-S/E2
Technical Data
1
3
0
8
6
3
2
0
1
9
-0
4
15
5
Technical Data
Figure 5.1
General Data
Functional Safety Data
Indicators/Operating Elements
Electrical Data
Slave type
Safety slave
UL file number
E223772
Safety Integrity Level (SIL) SIL 3
Performance Level (PL)
PL e
MTTF
d
200 a
PFH
d
0
PFD
0
FAULT LED
Fault indication; LED red
Red: communication fault or address is 0
Red, flashing: output voltage overload
PWR LED
AS-Interface voltage; green LED
AUX LED
Ext. auxiliary voltage U
AUX
; green LED
IN LED
Switching state (input); 2 yellow LEDs
OUT LED
Switch state (output); 2 yellow LEDs
Auxiliary power (output)
20 VDC ... 30 VDC PELV
Rated operating voltage
26.5 V ... 31.6 V from AS-Interface
Rated operating current
≤
70 mA
Protection class
III
Surge protection
U
AUX
, U
e
: Overvoltage category II, securely isolated power
supplies (PELV)
99.6
48.5
50.5
22.5