Pepperl+Fuchs schmersal RSS260 AS Operating Instructions Manual Download Page 1

RSS260 AS

Operating instructions

Safety sensor

EN

1

1. About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The Schmersal range of products is not intended for private consumers. 

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Actuating directions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.3  Switching distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.4  Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.5  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.6  Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .5

5  Functions and configuration

5.1  Programming the slave address  . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5.2 

Configuration of the safety monitor

  . . . . . . . . . . . . . . . . . . . . . . . . .5

5.3  Status signal "safety release"  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5.4  Actuator teaching / actuator detection . . . . . . . . . . . . . . . . . . . . . . .5

6  Diagnostic

6.1  LED indications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.2  Error. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.3  Diagnostic information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.4  Diagnostic signal periphery error . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.5  Read-out of the parameter port  . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

7  Set-up and maintenance

7.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

7.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

8  Disassembly and disposal

8.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

8.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

9  EU Declaration of conformity

x.000 / 03.2022 / v

.A.   -   103015221-EN / D / 2022-03-15 / 

AE-Nr

. 14783

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Original

Cross Reference:

Schmersal 

Article number

Schmersal 

Description

Fuchs 

Article number

Fuchs 

Description

103004641

RSS260-I2-ST-AS 319858

103004318

RST260-1

319859

VAA-1E-IEI3-READER1-S-V31
VAZ-IEI3-TAG1-S

Summary of Contents for schmersal RSS260 AS

Page 1: ...responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description Content 1 About this doc...

Page 2: ...ronic safety sensor is designed for application in safety circuits and is used for monitoring the position of movable safety guards In this application the safety sensor monitors the position of hinged sliding or removable safety guards by means of the coded electronic actuator The safety function consists of safely switching off the code transmission when the safety guard is opened and maintainin...

Page 3: ...essly approved by K A Schmersal GmbH Co KG could void the user s authority to operate the equipment L émetteur récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d Innovation Sciences et Développement économique Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 L appareil ne doit pas produire de bro...

Page 4: ... the yellow LED signals the actuator detection the flashing of the yellow LED after a delay signals that the safety sensor is actuated in the hysteresis area Recommended Adjustment Align the safety sensor and actuator at a distance of 0 5 x sao The correct functionality of both safety channels must be checked by means of the connected safety monitoring module 3 5 Dimensions All measurements in mm ...

Page 5: ...varying SaW code of a Safety at Work slave are evaluated through an OR operation with 4 inputs in the control system 5 4 Actuator teaching actuator detection Safety sensors with standard coding are ready to use upon delivery Individually coded safety sensors and actuators will require the following teach in procedure 1 Switch the safety sensor s voltage supply off and back on 2 Introduce the actua...

Page 6: ...Off 1 static 0 Internal device error periphery error red green flashing Flashes 1 1 static 0 AS i error slave address 0 or communication error red depending on the condition 0 static 0 1 refer to flash code Table 2 Error messages flash codes yellow LED Flash codes yellow Designation Autonomous switch off after Error cause 4 flash pulses Ambient temperature high 0 min Ambient temperature too high T...

Page 7: ...nctionality A regular visual inspection and functional test including the following steps is recommended 1 Check the safety function 2 Check the fixing and integrity of the safety switchgear the actuator and the cable 3 Remove possible metal chips Measures must be taken to protect against manipulation or against the bypassing of safety device for example using an extra actuator Damaged or defectiv...

Reviews: