42
Radar motion sensors RMS-D, RMS-D-RC, RMS-D BROAD, RMS-D-NA, RMS-D-RC-NA
Operation
You can also program the sensor with the RMS remote control if the sensor model number includes -RC, even if
the cover is in place. In this case the sensor address must be set previously.
7
Operation
You can download a selection of Comfort settings on the Internet from www.pepperl-fuchs.com.
7.1
Setting the Sensing Area
To adjust the position of the sensor, hold the printed circuit board by its edge, gently pull it forward, then place it in
the desired position.
The sensor's position can be adjusted in 5° increments from 0° to 40°. The default setting from the factory is 15°.
Notches can be broken off to make a different angle setting. The sensor's printed circuit board can also be inserted
at a slant. Do not angle the board to the right or the left by more than 3 notches from the opposite side.
Figure 7.1:
Electronics - position of options
Set-up
To place the sensor in operation, follow these steps:
1.
Turn on the power supply.
2.
Wait until the red / green LED on the sensor is no longer flashing (10 seconds)
3.
Set the desired size and position of the sensing area on the RMS-D.
4.
Check the settings by walking through the sensing area.
1
2
2
40°
0°
0°
5°
40°