2
0
1
9
-0
2
14
Commissioning
6
Commissioning
6.1
Programming the Switching Outputs
2 switching windows with a window width of 5
°
(+/- 2.5
°
) are preset at the factory. The switching
windows lie between the angle settings 117.5
°
... 122.5
°
(S1), and 237.5
°
... 242.5
°
(S2). You
can modify the position and width of these switching windows by programming them
accordingly. The start and end points of a switching window can be defined at any desired
position. The smallest angle range of a switching window can be 5
°
and the largest angle range
can be 360
°
.
To ensure reliable switching characteristics, each switching output has a switching hysteresis
of 1
°
when switched off, which prevents the electrical output signal from wavering.
The switching hysteresis is located at the top or bottom end of the switching window,
depending on the direction of rotation of the actuator element. The following graphic illustrates
the switching characteristics in principle, using the example of the sensor at switching output
S1.
Figure 6.1
S11
S12 S12+H
H
S11-H
S12
H
S11
Signal at switching output
Angle position
Direction of rotation
actuator
Angle position
Note!
Unlocking the buttons
If the keylock is active, it must first be deactivated. The sensor indicates that the keylock is
active by changing the color of the "Power/Error" LED to red when a button is pressed. To
unlock the buttons, press and hold the S1 and S2 buttons simultaneously for 3 seconds. The
color of the "Power/Error" LED changes to green. The buttons are no longer locked.