Intended use

The inductive angle positioning system PMI360DV-F130... was designed for position detection 

on valve actuators or valves. In addition to these main applications, the inductive angle posi

-

tioning system PMI360DV-F130... is also suitable for the precision, non-contact detection of all 

movement sequences in applications where machine or system components rotate or swivel 

around an axis with a maximum diameter of 41.5 mm.

3.3

General safety instructions

Responsibility for planning, assembly, commissioning, operation, maintenance, and dismount

-

ing lies with the plant operator.
Installation and commissioning of all devices may be performed only by trained and qualified 

personnel.
It is dangerous for the user to carry out modifications and/or repairs and doing so will void the 

warranty and exclude the manufacturer from any liability. In the event of any serious errors, stop 

using the device. Secure the device against unintended operation. To have the device repaired, 

return it to your local Fuchs representative or your sales center. 

Danger!

This symbol indicates an imminent danger.
Non-observance will result in personal injury or death.

Warning!

This symbol indicates a possible fault or danger.
Non-observance may cause personal injury or serious property damage.

Caution!

This symbol indicates a possible fault.
Non-observance could interrupt the device and any connected systems and plants, or result in 

their complete failure.

Note

This symbol brings important information to your attention.

Note
Disposal

Electronic waste is hazardous. When disposing of the equipment, observe the current statutory 

requirements in the respective country of use, as well as local regulations. 

Summary of Contents for PMI360DV-F130-IU-V15

Page 1: ...PMI360DV F130 IU V15 Inductive angle positioning system Manual...

Page 2: ...ion as well as the supplementary clause Expanded reservation of proprietor ship Worldwide Pepperl Fuchs Group Lilienthalstr 200 68307 Mannheim Germany Phone 49 621 776 0 E mail info de pepperl fuchs c...

Page 3: ...ssories 8 4 4 1 Connection Cables 9 4 4 2 Actuator 9 5 Installation 10 5 1 Note on safety 10 5 2 Mounting 10 5 3 Electrical connection 12 6 Commissioning 13 6 1 Programming the analog output 13 7 Outp...

Page 4: ...orldwide scale Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any questions about the devic...

Page 5: ...eveloped and manufactured in line with the applicable European standards and directives The product manufacturer Pepperl Fuchs Group 68307 Mannheim Germany has a certified quality assurance system tha...

Page 6: ...s may be performed only by trained and qualified personnel It is dangerous for the user to carry out modifications and or repairs and doing so will void the warranty and exclude the manufacturer from...

Page 7: ...3 3 k the angular position is output as a voltage value 0 10 V DC and for low resistance loads 400 as a current value 4 20 mA The actuator BT F130 A see chapter 4 4 is usually attached to the rotary s...

Page 8: ...ding on the current operating state of the device The LED I U is yellow and indicates the status of the device during the programming process and normal oper ation The programming button is used to pr...

Page 9: ...ic interference please use shielded single ended female cordsets from our extensive range of accessories 4 4 2 Actuator The BT F130 A actuator is designed for mounting directly on the drive shaft or a...

Page 10: ...is positioned in the center of the sensor so that the actuator does not rub against the sensor housing while the actuator is rotating Warning Risk of short circuit Working on live parts can cause inj...

Page 11: ...ive mate rial B or inserted in this ring Dimensions when using a different actuating element A Drive shaft B Insulation ring made from non conductive material C Different actuator L 23 mm D Sensitive...

Page 12: ...ectrical interference 4 Check that the wires are connected correctly before connecting the cordset to the sensor On Pepperl Fuchs cordsets the wire colors are assigned to the connecting pins in the co...

Page 13: ...art point of the analog ramp 3 Move the actuator to the position that you wish to define as the start point of the analog ramp and then press the I U button The yellow I U LED lights up for 2 seconds...

Page 14: ...you intend to program an angle segment of exactly 360 for the analog output you can make use of the restriction that prevents the angle segment from exceeding 360 In the second step of the angle segm...

Page 15: ...e The function of the analog output depends on whether the output assumes the function of a voltage or a current output de pending on the load Current output If the measurement range is exceeded the a...

Page 16: ...e corre sponding yellow LED lights up If the actuator rotates beyond the limits of the programmed measurement range the LED goes out The output logic depends on whether the analog out put assumes the...

Page 17: ...nsing range of the angular positioning system and the output value is updated Note Special feature when the system is switched on with a voltage output If a high resistance load is connected to the se...

Page 18: ...sing the button on the sensor Default setting PMI360DV F130 IU V15 Reset process 1 Press and hold the sensor button The associated yellow LED starts to flash slowly after 2 seconds 2 Continue to hold...

Page 19: ...lights up red during programming Actuator lost during the parameterization process or distance between actuator and surface of sensor too great own actuator Make sure that the concentric ity and adjus...

Page 20: ...or used is mounted correctly or install an actuator with appropriate dimensions at the correct dis tance from the sensor see chapter 5 2 Analog current output yields a value of approx 3 6 mA No actuat...

Page 21: ...sal Electronic waste is hazardous waste When disposing of the equipment observe the current statutory requirements in the respective country of use as well as local regulations The device does not con...

Page 22: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www pepperl fuchs com Pepperl Fuchs Subject to modifications Printed in Germany DOCT 2048C...

Reviews: