Pepperl+Fuchs PMI360DV-F130-IU-V15 Manual Download Page 11

PMI360DV-F130-IU-V15

Installation

 2

02

0-

01

11

Using a different actuating element

The BT-F130-A actuator included can be replaced with a different actuator, provided that the 

new actuator fits in the sensor opening. When using a different actuator element, the element 

must fulfill all requirements relating to the material, dimensions and distance to the sensitive 

surface on the sensor (see table). Failing to fulfill all of these requirements may reduce the 

accuracy/resolution of the sensor or even prevent it from functioning. 

The actuator (C) can be placed on the insulating ring made from non-conductive mate

-

rial (B) or inserted in this ring.

Dimensions when using a different actuating element

A

Drive shaft

B

Insulation ring made from non-conductive material

C

Different actuator (L 

≥ 23 mm)

D

Sensitive surface on the sensor (black, cylindrical inner surface)

D

Sensor

F

Insert the shaft until actuator C and the sensitive surface on sensor D overlap as 

much as possible.

Dimension

Value

t

2 mm

w

7.5 mm

d1

Depends on the drive shaft material

AR (previously St37-2): max. 19 mm

Stainless steel 1.4435/AISI 316L (V4A): max. 21 mm

Stainless steel 1.4305/AISI 303 (V2A): max. 23 mm

d2

Select so that the distance between the edges of the actuator and the 

sensitive surface on the sensor is 1 mm 

 2 mm.

d3

41.5 mm

Actuator material

Construction steel such as AR (previously St37-2)

w

A

C

D

E

B

F

t

d1

d2

L

d3

Summary of Contents for PMI360DV-F130-IU-V15

Page 1: ...PMI360DV F130 IU V15 Inductive angle positioning system Manual...

Page 2: ...ion as well as the supplementary clause Expanded reservation of proprietor ship Worldwide Pepperl Fuchs Group Lilienthalstr 200 68307 Mannheim Germany Phone 49 621 776 0 E mail info de pepperl fuchs c...

Page 3: ...ssories 8 4 4 1 Connection Cables 9 4 4 2 Actuator 9 5 Installation 10 5 1 Note on safety 10 5 2 Mounting 10 5 3 Electrical connection 12 6 Commissioning 13 6 1 Programming the analog output 13 7 Outp...

Page 4: ...orldwide scale Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any questions about the devic...

Page 5: ...eveloped and manufactured in line with the applicable European standards and directives The product manufacturer Pepperl Fuchs Group 68307 Mannheim Germany has a certified quality assurance system tha...

Page 6: ...s may be performed only by trained and qualified personnel It is dangerous for the user to carry out modifications and or repairs and doing so will void the warranty and exclude the manufacturer from...

Page 7: ...3 3 k the angular position is output as a voltage value 0 10 V DC and for low resistance loads 400 as a current value 4 20 mA The actuator BT F130 A see chapter 4 4 is usually attached to the rotary s...

Page 8: ...ding on the current operating state of the device The LED I U is yellow and indicates the status of the device during the programming process and normal oper ation The programming button is used to pr...

Page 9: ...ic interference please use shielded single ended female cordsets from our extensive range of accessories 4 4 2 Actuator The BT F130 A actuator is designed for mounting directly on the drive shaft or a...

Page 10: ...is positioned in the center of the sensor so that the actuator does not rub against the sensor housing while the actuator is rotating Warning Risk of short circuit Working on live parts can cause inj...

Page 11: ...ive mate rial B or inserted in this ring Dimensions when using a different actuating element A Drive shaft B Insulation ring made from non conductive material C Different actuator L 23 mm D Sensitive...

Page 12: ...ectrical interference 4 Check that the wires are connected correctly before connecting the cordset to the sensor On Pepperl Fuchs cordsets the wire colors are assigned to the connecting pins in the co...

Page 13: ...art point of the analog ramp 3 Move the actuator to the position that you wish to define as the start point of the analog ramp and then press the I U button The yellow I U LED lights up for 2 seconds...

Page 14: ...you intend to program an angle segment of exactly 360 for the analog output you can make use of the restriction that prevents the angle segment from exceeding 360 In the second step of the angle segm...

Page 15: ...e The function of the analog output depends on whether the output assumes the function of a voltage or a current output de pending on the load Current output If the measurement range is exceeded the a...

Page 16: ...e corre sponding yellow LED lights up If the actuator rotates beyond the limits of the programmed measurement range the LED goes out The output logic depends on whether the analog out put assumes the...

Page 17: ...nsing range of the angular positioning system and the output value is updated Note Special feature when the system is switched on with a voltage output If a high resistance load is connected to the se...

Page 18: ...sing the button on the sensor Default setting PMI360DV F130 IU V15 Reset process 1 Press and hold the sensor button The associated yellow LED starts to flash slowly after 2 seconds 2 Continue to hold...

Page 19: ...lights up red during programming Actuator lost during the parameterization process or distance between actuator and surface of sensor too great own actuator Make sure that the concentric ity and adjus...

Page 20: ...or used is mounted correctly or install an actuator with appropriate dimensions at the correct dis tance from the sensor see chapter 5 2 Analog current output yields a value of approx 3 6 mA No actuat...

Page 21: ...sal Electronic waste is hazardous waste When disposing of the equipment observe the current statutory requirements in the respective country of use as well as local regulations The device does not con...

Page 22: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www pepperl fuchs com Pepperl Fuchs Subject to modifications Printed in Germany DOCT 2048C...

Reviews: