Appendix
2
0
1
9
-0
2
31
11.3.3
IO-Link Device Parameters
Note!
The existing indexes for the various sensors differ according to their properties. For example,
indexes for parameterizing an analog output are only available for sensors with an analog
output.
The same is true for the parameter values within an index. For example, settings for an analog
current output are not available for a sensor with an analog voltage output.
A list of the available indexes can be found on the datasheet for your IO-Link sensor at
www.pepperl-fuchs.com
.
Index
(hex)
Sub Name
Type
Data
type
Value
Default
Unit
Smart Sensor Profile parameters
0x3A
Teach-in channel
R/W
uint8
0 ... 3
0
0x3B
Teach-in status
R
uint8
0x3C
BD1_SPV
—
switching signal 1
R/W
record
1
SP1
—
setpoint
value 1
R/W
uint16
0 ... 448
112
1/32 mm
2
SP2
—
setpoint
value 2
R/W
uint16
0 ... 448
144
1/32 mm
0x3D
BD1_SPC
—
switching signal 1
configuration
R/W
record
1
switchpoint logic
R/W
uint8
0x00
—
not
inverted
0x01
—
inverted
0x02
–
0xFF
—
not allowed
0x00
2
switchpoint mode
R/W
uint8
0x00
—
inactive
0x01
—
single-
point mode
0x02
—
window
mode
0x03
—
two-
point mode
0x04
–
0x7F
—
reserved
0x80
—
centered
window mode
0x80
3
switchpoint
hysteresis
R/W
uint16
0: Normal
1: Medium
2: High
1
0x3E
BD2_SPV
—
switching signal 1
R/W
record
1
SP1
—
setpoint
value 1
R/W
uint16
0 ... 448
224
1/32 mm
2
SP2
—
setpoint
value 2
R/W
uint16
0 ... 448
256
1/32 mm
0x3F
BD2_SPC
—
switching signal 1
configuration
R/W
record