Summary of Contents for LS680-DA

Page 1: ...R LS680 DA Optical data coupler FACTORY AUTOMATION MANUAL...

Page 2: ...Terms of Delivery for Products and Services of the Electrical Industry published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in i...

Page 3: ...controls 12 4 3 Interfaces and connections 13 4 4 Delivery package 14 4 5 Accessories 14 4 5 1 Mounting accessories 14 4 5 2 Connecting cable 14 4 5 3 Network connecting cable 14 5 Installation 15 5...

Page 4: ...ize the device s entire range of functions reduce faulty operation and the associated errors reduce costs from downtime and incidental repairs increase the effectiveness and operating efficiency of yo...

Page 5: ...tion on your product at http www pepperl fuchs com Simply enter the product name or model number in the Product Key word search box and click Search Select your product from the list of search results...

Page 6: ...ed and manufactured under observance of the applicable European standards and guidelines The product manufacturer Pepperl Fuchs GmbH D 68307 Mannheim has a certified quality assurance system that conf...

Page 7: ...on and commissioning of all devices must be performed by a trained professional only User modification and or repair are dangerous and will void the warranty and exclude the manufacturer from any liab...

Page 8: ...people Do not observe with optical instruments such as magnifying glasses microscopes telescopes or binoculars Install the device so that the warning is clearly visible and readable Maintenance and re...

Page 9: ...carried out by authorized service personnel Warning Rayonnement laser invisible produit laser classe 1M Ne pas regarder le rayon laser invisible avec des instruments optiques comme les loupes microsc...

Page 10: ...tion and or repair are dangerous and will void the warranty and exclude the manufacturer from any liability If serious faults occur stop using the device Secure the device against inadvertent operatio...

Page 11: ...h the bus system in question All layer 2 telegrams IEEE 802 3 Clause 25 are physically transported There is no saving of telegrams so the transfer is not delayed at all Modules operating at a data rat...

Page 12: ...ing of the LAN LED indicates the presence of data packets on the LAN OPT Status of the optical connection The OPT LED flashes when the optical connection is stabilized through correct alignment SIGNAL...

Page 13: ...ure 4 1 Power supply and alarm output connection layout Service The 8 pin M12 connector on the rear of the housing is for service purposes Network There is a 4 pin D coded M12 socket on the rear of th...

Page 14: ...ervice connector Designation Description V1 G 2M PVC Female cordset straight M12 4 pin PVC cable length 2 m V1 G 2M PUR Female cordset straight M12 4 pin PUR cable length 2 m V1 M 5M PVC Female cordse...

Page 15: ...ship the unit at a later time 5 2 Mounting The device has two mounting holes as well as four retaining feet for easy installation M4 inserts can also be pressed into these four feet This allows existi...

Page 16: ...hat the levers can be released outwards as far as the stop if necessary the optical data coupler has to be pressed down applying some force from the top to the center 5 3 Connection Connecting the pow...

Page 17: ...gnment for PROFINET or Ethernet IP The LS680 automatically locates transmit and receive lines Auto MDIX so no crossover cable has to be used To connect the sensor to a network proceed as follows 1 Plu...

Page 18: ...ontally and vertically with the other optical data coupler device The drop off in intensity at the edge of the spot is very pronounced which makes the edges easy to locate Figure 6 1 Explanation of di...

Page 19: ...ent alignment aid Connect the power supply Power 3 Roughly align the device at a distance of around 3 5 m until both signal indicators lie in the green zone Ensure that the optical data couplers are a...

Page 20: ...ction Parallel light paths If two transmission paths are installed next to each other without any optical separation then the optical data couplers must be installed opposite in pairs to avoid cross t...

Page 21: ...l Ethernet adapter is permanently set to 100 MBit full duplex as this is the only format that is converted for the optical transmission Any adjustments required to connection modes must be made using...

Page 22: ...the device in water Do not spray the device with water or other fluids Do not use a scouring agent to clean the surface of the device Use a cotton or paper cloth moistened with water or isopropyl alco...

Page 23: ...control cabinet Check whether there is a reason why it is switched off installation or maintenance work etc Switch the power supply on if appropriate Check the wiring carefully and repair any wiring f...

Page 24: ...inal ratings Note INVISIBLE LASER RADIATION DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS Laser class 1M Wave length device F1 785 nm Wave length device F2 660 nm Pulse length 8 ns Repetition rate 62...

Page 25: ...t indication output 1 PNP inactive when falling short of the stability control short circuit protected max 200 mA Directive conformity EMC Directive 2004 108 EC Standard conformity Standards EN 61000...

Page 26: ...GmbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Paci...