16 - EN
WARNING DEVICE LAL-SRW3
Installation
EN
3.3
Connection
Read the Safety chapter, paying particular attention to the section covering
Installation and Commissioning (see chapter 1.7) before connecting the device.
Do not remove the identification plate.
Take care not to reverse the polarity when connecting the sensor cable. The loop
resistance of the extension cable should not exceed
■
20
Ω
for the sensor KVF-104-PF, SLU-103-**.
■
10
Ω
for the sensor NVF-104/34-PF.
Warning!
Risk of short circuit
Injuries and damage to the device are possible when working with live parts.
■
Before working on the device, always disconnect the supply voltage.
■
Connect the device to the supply voltage only after completion of the work.