IC-KP-B6*
Communication in "IVI-B6" mode
2
011-
08
17
Command identifier (B4 ... B1)
Command parameters B4 ... B1 are used to define the relevant command.
Double side mode (DS)
This function enables double-sided writing/reading. If this bit is set (DS = 1), type
ICC-50, IDC-50 and IDC-CARD read only and read/write tags can be read and
written from both sides. Otherwise read only and read/write tags can only be read
from the labeled side.
Command identifier B4 ... B1
15
14
13
12
Bit no.
B4
B3
B2
B1
Meaning
0
0
0
0
No command
0
0
0
1
SF
0
0
1
0
AF
0
0
1
1
BF
0
1
0
0
SR
0
1
0
1
AR
0
1
1
0
BR
0
1
1
1
SW
1
0
0
0
AW
1
0
0
1
BW
1
0
1
0
SB
1
0
1
1
AB
1
1
0
0
BB
1
1
0
1
EF
1
1
1
0
ER
1
1
1
1
EW
Note!
In double side mode, the execution time of the read/write commands increases.