20
13-
02
56
Commands
The address of the first and last data word to be written is based on the absolute
address of the read/write tag (not the <WordAddr>). The address 03h is therefore
the first available word in the data range.
Byte
Bit no.
7
6
5
4
3
2
1
0
Byte 0
0
0
0
1
0
0
1
0
Single write configuration
12h
Byte 1
-
-
-
-
0
0
1
<T>
Channel (=1)
02h/03h
Byte 2
-
-
-
-
-
-
-
-
-
-
Byte 3
0
0
0
0
0
0
1
0
Word address in the
configuration range
(=control word)
02h
Byte 4
0
0
0
0
0
0
0
0
Bits 16 to 31 of the control
word
00h
Byte 5
0
0
0
0
0
0
0
0
00h
Byte 6
0
0
0
0
0
0
1
1
Address of the last data word
to write
03h
Byte 7
0
0
0
0
0
0
1
1
Address of the first data word
to write
03h