Parameter Index Definitions
201
8-0
2
11
5.5
Parameter Index 05, Cyclic Timer
5.6
Parameter Index 07, Baudrate
5.7
Parameter Index 08, Node ID
5.8
Parameter Index 09, Termination Resistor
Type
Description
data type
unsigned 16
access
r/w
default
0x32 = 50 (50 ms)
function
cyclic timer
values
0: stop cyclic data transmission
n: transmitts data every n milliseconds
Type
Description
data type
unsigned 16
access
r/w
default
0x04
function
baudrate setting
values
00h: 20 kbit/s
01h: 50 kbit/s
02h: 100 kbit/s
03h: 125 kbit/s
04h: 250 kbit/s
05h: 500 kbit/s
06h: 800 kbit/s
07h: 1000kbit/s
Type
Description
data type
unsigned 8
access
r/w
default
32
function
Node ID setting
values
1 ... 253
Type
Description
data type
unsigned 8
access
r/w
default
0
function
termination resistor activation/de-activation
values
1: on
0: off