CP345
Installation
ID 19979, Rev. 03
Page 3 - 4
®
PEP Modular Computers GmbH
3.1.1
Board Location in the System
Board location within a system must be considered carefully. Depending on the number of
CP345 boards, their locations in a given system and the operating system being used, appli-
cation programs may have difficulty to identify boards properly. In particular, when configura-
tion changes such as board replacement, movement to another slot etc. are made after the
initial system implementation. Therefore, any changes made to a system should be carefully
considered before making the change, and proper operation be verified before the system is
put into operation again.
3.1.2
Cabling
3.1.2.1 Four-Channel Frontpanel Adapter
In order to provide separate serial I/O channelling, a four-channel frontpanel adapter
(CP-ADAP-CP345-DSUB50) can be connected to the 50-pin frontend connector of the optoi-
solated variant of the CP345 mainboard (CP345-OPT) or the optoisolated rear I/O module
(CP-RIO-345-OPT) of the rear-I/O capable board (CP345-RIO). This adapter terminates on
the user side with four male 9-pin D-Sub connectors which include the signals of channels 0 to
3. The adapter cables have a length of approx. 15 cm.
The pinouts of the adapter’s 50-pin and 9-pin DSub connectors are shown in the Functional
Description chapter of this manual.
Note...
When configuring a system it is recommended that all boards to be
used first be installed in the system prior to installing any drivers or
other board related software. Failure to do so may result in the non-
identification of a given board or boards.
Channel 0
Channel 1
Channel 2
Channel 3
9-pin D-Sub
50-pin D-Sub
Connectors
Connector
Figure 3-1: Four-Channel Front-
panel Adapter
Summary of Contents for CP345
Page 3: ...CP345 Preface Preface ID 19979 Rev 03 Page iii PEP Modular Computers GmbH ...
Page 4: ...This page was intentionally left blank ID 19979 Rev 03 Page iv PEP Modular Computers GmbH ...
Page 12: ...This page was intentionally left blank ID 19979 Rev 03 Page xii PEP Modular Computers GmbH ...
Page 16: ...This page was intentionally left blank ID 19979 Rev 03 Page xvi PEP Modular Computers GmbH ...
Page 21: ...CP345 Introduction Introduction ID 19979 Rev 03 Page 1 1 PEP Modular Computers GmbH Chapter 1 ...
Page 22: ...This page was intentionally left blank ID 19979 Rev 03 Page 1 2 PEP Modular Computers GmbH ...
Page 34: ...This page was intentionally left blank ID 19979 Rev 03 Page 2 2 PEP Modular Computers GmbH ...
Page 49: ...CP345 ID 19979 Rev 03 Installation Page 3 1 PEP Modular Computers GmbH Installation Chapter 3 ...
Page 50: ... PEP Modular Computers GmbH This page was intentionally left blank ...
Page 56: ... PEP Modular Computers GmbH This page was intentionally left blank ...
Page 58: ...This page was intentionally left blank ID 19979 Rev 03 Page 4 2 PEP Modular Computers GmbH ...
Page 60: ...This page was intentionally left blank ID 19979 Rev 03 Page 4 4 PEP Modular Computers GmbH ...
Page 62: ...This page was intentionally left blank ID 19979 Rev 03 Page 5 6 PEP Modular Computers GmbH ...
Page 80: ...This page was intentionally left blank ID 19979 Rev 03 Page 5 24 PEP Modular Computers GmbH ...