Operators manual for the Pentruder 6-12HF and Pentpak HF-power pack – Original instructions
Page
37
Service on the rotating
blade guard flange:
The blade guard holding flange consists of a nylon flange bolted to the
saw arm. Around the nylon flange there is an aluminium outer flange that
rotates with the blade guard as the arm rotates.
The whole assembly must be disassembled, cleaned and greased
regularly to function well.
1. Remove the blade flange from the spindle.
2. Remove the 16 M4 countersunk screws and remove the stainless steel
ring.
3. Remove the 16 M4 Allen Screws and take off the flange.
4. Disassemble the various parts and clean in a solvent.
5. Grease all parts and replace worn O-rings. See spare parts manual for
part numbers and sizes.
6. Assemble all parts and be sure O-rings are well covered in grease.
Preferably use water resistant grease.