101
Aim at the Target 1 and press [F1] [MEAS] to
measure a distance. The distance between
Reference point and Target point 1 is displayed.
V.dst. and % grade are displayed by minus mark when the Target point height is at a lower
position.
Press the [F3] [DATA] to view the TARGET
POINT screen.
10.3 Target - Target distance
Aim at the Target 2 and press [F1] [MEAS] to
measure a distance.
The distance between Reference point and Target
point 2 is displayed.
Press [F5] [DISP] to display the Target - Target
distance.
10.4 New Reference point selection
Press [ENT] to view the REF. POINT SELECTION
screen.
New Ref. point can be selected.
Press the [F5] [ENT] to view the TARGET POINT
screen. Reference point is changed.
Input the new PH and repeat the same procedure as
the above.
Summary of Contents for R-422VN
Page 92: ...91...