background image

 

 

 

 

IMPORTANT: The movement of the adjustment screws must be very low! One 

turn of the adjustment screw moves the laser dot by approx 20 cm at a 10m 

distance. 

 

GLS17 laser simulator setting - Battery change 

 

Change the battery when the LED indicator flashes  once. 

 

Remove the battery cover (A) from the pistol body (B). 

 

 

 

Remove the empty battery using the ribbon and insert a new one (AAA 1,5V). Pay attention 

to the correct battery polarity! Reinstall the cover onto the pistol body. 

 

 

 

 

Summary of Contents for GLS 17

Page 1: ...real weapon Do not look into the laser beam directly or through any optical device Read the Operating Instructions carefully before using the GLS laser simulator Don t use the device for purposes othe...

Page 2: ...2 Description 1 Front sight 2 Battery cover battery 3 Loading lever 4 Rear sights 5 Universal grip with rubber surface 6 Trigger 7 Starting magnet...

Page 3: ...ts 5 Anatomical grip with rubber surface 6 Trigger 7 Starting magnet 3 Intended use GLS 17 laser simulator is designed for use within instructional courses trainings or modern pentathlon competitions...

Page 4: ...tor change the battery change the gun stock set the trigger position Laser beam parameters can only be changed by the manufacturer or an authorized person The simulator owner must confirm his consent...

Page 5: ...flashing continuously blue means the battery is empty and the battery should be changed immediately After the battery test run the LED light remains constantly blue to indicate the laser is on The la...

Page 6: ...Turning the screw 10b clockwise laser dot goes upward Turning the screw 10b counterclockwise laser dot goes downward...

Page 7: ...cm at a 10m distance GLS17 laser simulator setting Battery change Change the battery when the LED indicator flashes once Remove the battery cover A from the pistol body B Remove the empty battery usi...

Page 8: ...GLS 17 laser simulator setting Trigger Position Setting There are 3 available trigger positions Unscrew trigger 11 and screw in the requested position...

Page 9: ...cloth Do not use any cleaning agents solvents or chemical preparations Do not push the emissive hole optic with any object 9 Possible Defects and Their Removal The laser beam trace is visible with di...

Page 10: ...module type PENTASHOT FLP20 Laser class I in accordance with EN 60825 1 2014 Wavelength 650 nm Laser beam diameter 4 5 mm 10 10 m Laser coding 15 6 ms UIPM laser signal Laser class certificate No 117...