background image

8 / 8

THERMAL MANAGEMENT SOLUTIONS

EN-TraceTekTTNRM-IM-H57474      01/13

WWW.THERMAL.PENTAIR.COM

© 2003-2013 Pentair. 

NORTH AMERICA 

Tel:  +1.800.545.6258

Fax:  +1.800.527.5703

Tel:  +1.650.216.1526

Fax:  +1.650.474.7215

[email protected]

EuROPE, MIddLE EAsT, AfRICA

Tel:  +32.16.213.511

Fax:  +32.16.213.603

[email protected]

AsIA PACIfIC

Tel:  +86.21.2412.1688

Fax:  +86.21.5426.2917

[email protected]

LATIN AMERICA

Tel:  +55.11.2588.1400

Fax:  +55.11.2588.1410

[email protected]

Pentair and TraceTek are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the 

right to change specifications without prior notice.

ON

TxD

IO/RN

IO/ER

RxD

CRC

Address  x 1 

x 10

750-315

Power on

Communications

E. Update the TTDM-128 Network

TT-NRM units are controlled by a central TTDM-128. The 

Update Network Function in the TTDM-128 software must 

be triggered in order for the TTDM-128 to recognize new or 

changed TT-NRM units. Until this software function is run, 

the TTDM-128 will not control new TT-NRM units.

1.  Energize all TT-NRMs in the network.

Confirm that the RS-485 network is complete (all TT-

NRM and TTSIM units and the TTDM-128 are connected 

to the RS-485 bus), and that the power to each unit has 

been turned on.

2.  Use the TTDM-128 system software to update the network.

Note: When the TTDM-128 is first powered, it automati-

cally runs the “Update” function.
Run the TTDM-128 “Update Network” software function 

to trigger it to recognize new TT-NRMs. The TTDM-128 

User Manual (H56853) describes this software function 

in detail.

3.  If necessary due to problems or questions, check function 

of individual modules.
•  Verify that a TT-NRM is functioning by confirming that 

the power LED is illuminated.

•  Check all connections.
•  Check that all TT-NRM modules are securely seated 

on the DIN rail.

•  Confirm that the TT-NRM network does not have any 

duplicate RS-485 addresses.

•  Individual relays can be checked using TTDM Self-test/

NRM Relay test.

Summary of Contents for TraceTek TT-NRM Series

Page 1: ...cuments TTDM 128 Installation Manual H57341 TTDM 128 User Manual H56583 Specifications Function Provides relay outputs to switch power to contactors under control of the TTDM 128 Ambient operating ran...

Page 2: ...127 circuits of leak detection TT NRM units switch external alarm or control devices NRMs are connected to the TTDM 128 unit via a single RS 485 network 1 Network processor marked 750 315 2 2 channel...

Page 3: ...is powered with line voltage and switches relay contacts that may be connected to line volt age Select an electrical panel or enclosure considering the area classification i e non hazardous or hazardo...

Page 4: ...he right of the last relay module added Refer to the TT NRM Assembly diagram on page 2 for the proper order of module assembly Important Modules and or external equipment may be damaged if modules are...

Page 5: ...C Address x 1 x 10 WAGO 750 315 I 0 SYSTEM 24V 0V L L N N L L N N 01 02 15 16 750 517 750 517 750 600 Note Previous wiring omitted for clarity L N POWER SUPPLY Using WAGO Terminals Insert flat blade s...

Page 6: ...2 channel relay output modules as shown ON TxD IO RN IO ER RxD CRC Address x 1 x 10 WAGO 750 315 I 0 SYSTEM 24V 0V L L N N L L N N 01 02 15 16 750 517 750 517 750 600 L L N N 15 16 750 517 Note Previo...

Page 7: ...with unique addresses to be daisy chained together along a common bus To add a new unit to the network simply daisy chain the RS 485 bus from the last unit to the new one or insert the new unit betwe...

Page 8: ...e must be triggered in order for the TTDM 128 to recognize new or changed TT NRM units Until this software function is run the TTDM 128 will not control new TT NRM units 1 Energize all TT NRMs in the...

Reviews: