Design Data

Technical Data

Part Number

TEC24VCNTLR

TEC48VCNTLR

Rated Voltage (VDC)

24

48

Operating Range (VDC)

18 to 30

40 to 60

Current @ Rated Voltage (Amps)

17.2

8.6

Power (Watts)

410

410

Operating Temperature (°F/°C)

-40 to +149/ -40 to +65

-40 to +149/ -40 to +65

Alarm Output Rating

1A @ 30 VDC

0.5A @ 60VDC

0.3A @ 120VAC

1A @ 30VDC

0.5A @ 60VDC

0.3A @ 120VAC

Temperature Accuracy (°F/°C)

±3.6/2

±3.6/2

High Temperature Alarm (°F/°C)

27/15 above cooling 

setpoint

27/15 above cooling 

setpoint

Low Temperature Alarm (°F/°C)

* 18/10 below heating 

setpoint, N/A if heating is 

disabled.

* 18/10 below heating 

setpoint, N/A if heating is 

disabled.

* If heating is disabled, there is no low temp alarm.

Operation

The controller will command the TEC to cool if the temperature read by the thermistor is 

above the cooling setpoint, and heat if the temperature is below the heating setpoint. If 

the temperature read by the thermistor is between the cooling and heating setpoints, the 

controller will be in a standby mode with no power applied to the TEC modules.
When going from cooling to heating or heating to cooling, the control logic provides 

for a minimum ten minute delay when applying power to the peltier chips. The delay is 

an added feature to minimize the stress on the TEC modules and controller by assuring 

that the peltier chip internal temperatures are able to equalize before reversing the DC 

current through the chips. The delay will only affect the controller response in the unlikely 

circumstance that the system experiences a rapid temperature swing from above the 

cooling setpoint to below the heating setpoint, or visa versa.
The normally open (NO) alarm output contact will close when an alarm occurs. The 

normally closed (NC) contact will open when an alarm occurs.

LED and alarm connection status

Status

Red

Blue

Com-NO

Com-NC

OFF

OFF

OFF

Closed

Open

ON – Standby

OFF

OFF

Open

Closed

ON – Cooling

OFF

ON

Open

Closed

ON – Cooling/High Temp Alarm

Flashing

ON

Closed

Open

ON – Heating

ON

OFF

Open

Closed

ON – Heating/Low Temp Alarm

ON

Flashing

Closed

Open

ON – Temp Sensor Failure

Flashing

Flashing

Closed

Open

RSPSupply  -  1-888-532-2706 -  www.RSPSupply.com

http://www.RSPSupply.com/p-6058-Hoffman-TEC24VCNTLR-Thermoelectric-Temperature-Controller-24V.aspx

Summary of Contents for TEC24VCNTLR

Page 1: ...tions Pentair Technical Products 2100 Hoffman Way Anoka MN 55303 1 763 323 8200 1 763 576 3200 www McLeanCoolingTech com INSTRUCTION MANUAL Thermoelectric Temperature Controller TEC24VCNTLR TEC48VCNTL...

Page 2: ...ended wire gauges for wiring Power and earth ground inputs 14 AWG TEC Module and earth ground outputs 14 AWG Fan outputs 20 AWG Alarm outputs 20 AWG Description Source Destination AWG Input Power to C...

Page 3: ...SUPPLIED WIRING CUSTOMER SUPPLIED WIRING THERMISTOR HARNESS INCLUDED WITH CONTROLLER THERMOELECTRIC TEMPERATURE CONTROLLER ALARM OUT EARTH GROUND INPUT POWER WIRE TO TERMINAL 4 FOR THESE UNITS ONLY W...

Page 4: ...sition Temperature setpoint dip switch position tables Cool 1 2 3 Cooling Set Point F C ON ON ON 95 0 35 0 factory set ON ON OFF 90 5 32 5 ON OFF ON 86 0 30 0 ON OFF OFF 81 5 27 5 OFF ON ON 77 0 25 0...

Page 5: ...ode with no power applied to the TEC modules When going from cooling to heating or heating to cooling the control logic provides for a minimum ten minute delay when applying power to the peltier chips...

Page 6: ...in any way or 1 Buyer specified product is inappropriate for system or environment in which it is operating 2 Pentair Technical Products product modified in any way without prior written authorization...

Page 7: ...etermined by Pentair Technical Products not be covered under warranty Buyer will be responsible for all shipping charges and will be billed accordingly H Non warranty repairs are subject to a 75 minim...

Page 8: ...Protecting Electronics Exceeding Expectations Pentair Technical Products 2100 Hoffman Way Anoka MN 55303 1 763 323 8200 1 763 576 3200 www McLeanCoolingTech com RSPSupply 1 888 532 2706 www RSPSupply...

Reviews: