Pentair t29 Instruction Manual Download Page 18

© 2015 Pentair Equipment Protection

89104464

- 18 -

WARRANTY

Pentair Equipment Protection warrants that the Goods manufactured by Pentair Equipment Protection 

will be free from defects in material and workmanship for a period of one (1) year from the date of 

shipment by Pentair Equipment Protection, subject to the following conditions and exclusions:

A.  Conditions. All Goods must be installed and operated according to the following specifications:

1.  Maximum voltage variation no greater than plus or minus 10% of nameplate nominal rating;

2.  Maximum frequency variation no greater than plus or minus 3 Hz of nameplate nominal rating;

3.  Must not exceed minimum and maximum stated temperatures on the nameplate;

4.  Must not exceed (BTU/Hr) rating, including any heat sink as indicated on the nameplate;

5.  Refrigerant bearing Goods must not be restarted for a period of one (1) minute after intentional or 

accidental shut-off;

6.  The filters (if applicable) must be cleaned regularly;

7.  The Goods and any parts thereof must not be modified, unless prior written authorization is 

received from Pentair Equipment Protection; and

8.  All Goods must be installed and grounded in accordance with all relevant electrical and safety 

codes, as well as the National Electric Code and OSHA rules and regulations.

9.  All Goods must be installed in a stationery application, free of vibration.
A violation of any one of these conditions shall render the warranty hereunder void and of no effect.

B.  Exclusions. This warranty shall be void if product is misapplied in any way or:

1.  Buyer specified product is inappropriate for system or environment in which it is operating.

2.  Goods are not installed in accordance with Pentair Equipment Protection specifications.

3.  Removal or modification of Pentair Equipment Protection label affixed to product without written 

Pentair Equipment Protection approval.

Pentair Equipment Protection must be notified of a claim in writing not later than fourteen (14) days from 

the date when Buyer has become aware of such occurrence, or where the defect is such that it may cause 

damage, immediately, such notice containing a description of how the defect manifests itself. Failure to 

provide such prompt notice to Pentair Equipment Protection shall result in forfeiture of Buyer’s rights 

under this warranty.
In the event of a warranty claim, Buyer is to return defective goods to Pentair Equipment Protection in 

accordance with Pentair Equipment Protection Return Policy. Warranty period for repaired goods remains 

at 1 year from shipment of original goods. Pentair Equipment Protection sole obligation to Buyer under 

this warranty will be, at Pentair Equipment Protection option:

A.  Repair or replace Pentair Equipment Protection products or parts found to be defective in material or 

workmanship.

B.  Issue credit for the purchase price paid by Buyer relating to such defective Goods or part.

THIS WARRANTY CONSTITUTES THE ENTIRE WARRANTY WITH RESPECT TO THE GOODS AND IS IN 

LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF 

MERCHANTABILITY AND IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

RETURN AND REPAIR POLICY

Pentair Equipment Protection products that: (i) are made to order, (ii) have been modified by Buyer, (ii) 

have special finishes, or (iv) are determined by Pentair Equipment Protection to constitute “custom” 

products that cannot be returned to stock or resold to other Buyers, will not be accepted for return by 

Pentair Equipment Protection.
All returns require a Return Material Authorization number (RMA #), regardless of reason for return, 

whether it be for warranty or out of warranty repair. Returns without an RMA # will be refused by our 

Receiving Department. An RMA # is valid for 30 days.

Summary of Contents for t29

Page 1: ... 2015 Pentair Equipment Protection 89104464 Rev D P N 89104464 T SERIES Air Conditioner T29 Model INSTRUCTION MANUAL ...

Page 2: ...atic 115 V Without Heat 8 Wire Diagram and Schematic 115 V With Heat 9 Wire Diagram and Schematic 230 V Without Heat 10 Wire Diagram and Schematic 230 V With Heat 11 Temperature Control 12 Principles of Operation 12 MAINTENANCE 12 Compressor 12 Inlet Air Filter 12 How To Remove Clean or Install a New Inlet Air Filter 13 Condenser and Evaporator Blowers 13 Refrigerant Loss 13 TROUBLE SHOOTING 14 Ba...

Page 3: ...ITY BEFORE MOUNTING THE AIR CONDITIONER TO THE ENCLOSURE Refer to the nameplate for proper electrical current requirements and then connect the power cord to a properly grounded power supply Minimum circuit ampacity should be at least 125 of the amperage shown in the design data section for the appropriate model No other equipment should be connected to this circuit to prevent overloading Operate ...

Page 4: ...pright position during operation 5 When routing the drain tube caution should be taken to keep it from kinking or being elevated above the exit point of the air conditioner The drain tube must be on a continuous downward slope A slight elevation of the tube could result in secondary trap FAILURE TO FOLLOW THESE COULD RESULT IN OVERFLOWING OF THE CONDENSATE DRAIN PAN 6 Refer to top of nameplate for...

Page 5: ... 2015 Pentair Equipment Protection 89104464 5 DIMENSIONAL DRAWING ...

Page 6: ... 2015 Pentair Equipment Protection 89104464 6 MOUNTING CUTOUT DIMENSIONS ...

Page 7: ...3001 03HE Coil Evaporator 28 1001 00 28 1001 00 Compressor AE AK 89100365 89104088 Filter Air Reusable 89057619 89057619 Filter Dryer 52 6028 00 52 6028 00 Relay Compressor Start N A 89104095 Service Cord 52 6035 143 52 6035 141 Terminal Block 10 1003 03 10 1003 03 Thermal Overload Compressor N A 89112198 Cooling Thermostat SPST 55 100F 10 1061 16 10 1061 16 Optional Heating Thermostat 10 1061 16 ...

Page 8: ... 2015 Pentair Equipment Protection 89104464 8 WIRE DIAGRAMS AND SCHEMATICS WIRE DIAGRAM AND SCHEMATIC 115 V WITHOUT HEAT NOTE The actual unit options may vary see unit label ...

Page 9: ... 2015 Pentair Equipment Protection 89104464 9 WIRE DIAGRAM AND SCHEMATIC 115 V WITH HEAT 89101187 NOTE The actual unit options may vary see unit label ...

Page 10: ... 2015 Pentair Equipment Protection 89104464 10 WIRE DIAGRAM AND SCHEMATIC 230 V WITHOUT HEAT NOTE The actual unit options may vary see unit label ...

Page 11: ... 2015 Pentair Equipment Protection 89104464 11 WIRE DIAGRAM AND SCHEMATIC 230 V WITH HEAT NOTE The actual unit options may vary see unit label ...

Page 12: ...rge pressures Under no circumstances should the access fitting covers be loosened removed or tampered with Breaking of seals on compressor access fittings during warranty period will void warranty on hermetic system Recharging ports are provided for the ease and convenience of reputable refrigeration repair service personnel for recharging the air conditioner INLET AIR FILTER Proper maintenance of...

Page 13: ...RATOR BLOWERS Blower motors require no maintenance All bearings shafts etc are lubricated during manufacturing for the life of the motor If the condenser blower motor ambient blower should fail it is not necessary to remove the air conditioner from the cabinet or enclosure to replace the blower The condenser blower is mounted on its own bulkhead and is easily accessible by removing the front cover...

Page 14: ...ompressor starts Did condenser blower and compressor come on when the thermostat was turned on YES proceed to step 4 NO possible problem Defective thermostat Cabinet temperature is cooler than thermostat set point Replace Part 4 Are both blowers and the compressor running If not the unit will not cool properly 5 Check condenser Ambient or HOT air blower for airflow Is there airflow YES proceed to ...

Page 15: ...the compressor come on the thermostat needs to be replaced SYMPTOMS AND POSSIBLE CAUSES SYMPTOM POSSIBLE CAUSE Unit won t cool Clogged fins on coil s Dirty filter Blowers not running Compressor not running Compressor runs but has bad valves Loss of refrigerant Compressor tries to start but won t run Low line voltage at start Should be 10 rated voltage Compressor motor stuck Bad contactor Bad overl...

Page 16: ... 2015 Pentair Equipment Protection 89104464 16 NOTES ...

Page 17: ... 2015 Pentair Equipment Protection 89104464 17 NOTES ...

Page 18: ...ir Equipment Protection label affixed to product without written Pentair Equipment Protection approval Pentair Equipment Protection must be notified of a claim in writing not later than fourteen 14 days from the date when Buyer has become aware of such occurrence or where the defect is such that it may cause damage immediately such notice containing a description of how the defect manifests itself...

Page 19: ...is fee If approval is not received within 30 days material will be scrapped and all shipping expenses and corresponding analysis fees will be billed to Buyer E At Buyer s request Failure Analysis can be provided by Pentair Equipment Protection for warrantable goods at no charge Failure analysis for non warranty repairs are subject to a 150 per hour Engineering charge plus any other incurred testin...

Page 20: ... 2015 Pentair Equipment Protection 89104464 Rev D P N 89104464 Pentair Equipment Protection 2100 Hoffman Way Minneapolis MN 55303 USA 1 763 422 2211 1 763 576 3200 PentairProtect com ...

Reviews: